Influence of density-modulus relationships on the predicted biomechanical response of subject-specific mandibular finite element models: comparative analysis with experimental test data

Introduction Finite element (FE) analysis has become an essential tool for studying the biomechanical behavior of the mandible and predicting the mechanical performance of surgical and restorative interventions. The predictive accuracy of FE models, however, depends on underlying assumptions. Current models often rely on simplified homogeneous material assumptions and lack experimental comparison. Therefore, the present study aims to compare predictions from FE analyses with experimental test data to investigate the influence of heterogeneous density-modulus relationships on the biomechanical response of subject-specific FE models of the human mandible. Methods For this study, experimental testing with a universal testing machine and FE models of three human mandible specimens were developed in parallel. The experimental and computational boundary conditions included a 200 N load on the caudal side of the mandibular angle, embedding the condyles and fixing the incisor teeth or the left first molar for a central or unilateral load case, respectively. In the FE analysis, eight different density-modulus relationships were employed to represent the heterogeneous material of human bone. The global parameter stiffness and the local parameter surface strain were compared across different density-modulus relationships between predicted and experimental results. Results The experimental tests measured the bone stiffness and local surface strain, ranging from 1.6 - 4.1 N/μm and –108.3 - 44.9 μm/m, for the central load case, and from 0.9 ‐ 4.0 N/μm and –104.8 - 60.9 μm/m, for the unilateral load case. The FE analysis predicted them between 4.8 - 13.0 N/μm, –253.1 - 60.9 μm/m for the central load case and 3.2 - 11.1 N/μm, –288.0 - 94.0 μm/m for the unilateral load case. Consistency between experimental tests and FE predictions was better for global stiffness than for local surface strain, with variation depending on the subject and load case. Discussion Given the limitations of our experimental test setup and the simplified assumptions in the FE analysis, no density-modulus relationship used for the FE models consistently reproduced the measured biomechanical experimental data. The results of the FE analysis were highly dependent on the density-modulus relationships used, which highlights the need to conduct sensitivity analyses and further computational studies to develop mandible-specific material models.

Authors

Institutions

Publication Details

Journal
Frontiers in Bioengineering and Biotechnology
Published
2026-11-18
DOI
https://doi.org/10.3389/fbioe.2026.1954579
Primary Topic
Orthodontics and Dentofacial Orthopedics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Influence of density-modulus relationships on the predicted biomechanical response of subject-specific mandibular finite element models: comparative analysis with experimental test data

Michael Dau, Jessica Hembus, Jan‐Oliver Saß, Maeruan Kebbach et al.
Frontiers in Bioengineering and Biotechnology
Orthodontics and Dentofacial Orthopedics
article

Influence of density-modulus relationships on the predicted biomechanical response of subject-specific mandibular finite element models: comparative analysis with experimental test data

Michael Dau, Jessica Hembus, Jan‐Oliver Saß, Maeruan Kebbach, Rainer Bader, Iman Soodmand, Christopher Jabs, Daniel Thiele, Ann-Kristin Becker
article en

Abstract

Introduction Finite element (FE) analysis has become an essential tool for studying the biomechanical behavior of the mandible and predicting the mechanical performance of surgical and restorative interventions. The predictive accuracy of FE models, however, depends on underlying assumptions. Current models often rely on simplified homogeneous material assumptions and lack experimental comparison. Therefore, the present study aims to compare predictions from FE analyses with experimental test data to investigate the influence of heterogeneous density-modulus relationships on the biomechanical response of subject-specific FE models of the human mandible. Methods For this study, experimental testing with a universal testing machine and FE models of three human mandible specimens were developed in parallel. The experimental and computational boundary conditions included a 200 N load on the caudal side of the mandibular angle, embedding the condyles and fixing the incisor teeth or the left first molar for a central or unilateral load case, respectively. In the FE analysis, eight different density-modulus relationships were employed to represent the heterogeneous material of human bone. The global parameter stiffness and the local parameter surface strain were compared across different density-modulus relationships between predicted and experimental results. Results The experimental tests measured the bone stiffness and local surface strain, ranging from 1.6 - 4.1 N/μm and –108.3 - 44.9 μm/m, for the central load case, and from 0.9 ‐ 4.0 N/μm and –104.8 - 60.9 μm/m, for the unilateral load case. The FE analysis predicted them between 4.8 - 13.0 N/μm, –253.1 - 60.9 μm/m for the central load case and 3.2 - 11.1 N/μm, –288.0 - 94.0 μm/m for the unilateral load case. Consistency between experimental tests and FE predictions was better for global stiffness than for local surface strain, with variation depending on the subject and load case. Discussion Given the limitations of our experimental test setup and the simplified assumptions in the FE analysis, no density-modulus relationship used for the FE models consistently reproduced the measured biomechanical experimental data. The results of the FE analysis were highly dependent on the density-modulus relationships used, which highlights the need to conduct sensitivity analyses and further computational studies to develop mandible-specific material models.

Frontiers in Bioengineering and BiotechnologyVol. 14
Universitätsmedizin Rostock (DE), University of Rostock (DE)
ITI Foundation
Good health and well-being
Orthodontics and Dentofacial Orthopedics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon