Experimental investigation of the shell-side thermo-hydraulic performance of a central-tube-free continuous helical-baffle heat exchanger equipped with low-finned tubes
A central-tube-free continuous helical-baffle heat exchanger with integral low-finned tubes (HBHE-LF) was compared experimentally with a conventional segmental-baffle exchanger (SBHE) using oil and water. Across four test series, the HBHE-LF showed 28.58%–36.70% higher overall heat-transfer coefficients based on the respective reference areas. At matched nominal oil flow rates, shell-side pressure drop and heat duty were 18.14% and 6.62% lower on average, respectively. Accounting for fin efficiency gave shell-side heat-transfer coefficients of 506–945 W/(m2·K). The performance evaluation criterion ranged from 2.72 to 2.90. Empirical correlations were developed for the shell-side Nusselt number and friction factor.
Authors
- Ziye Ling (ORCID: https://orcid.org/0000-0001-6114-9114)
- 唐六华
- Xiaoming Fang
- Junjie Chen
- Taotao Huang
- Zhengguo Zhang
Institutions
- Wuhan Science and Technology Bureau (CN)
- South China University of Technology (CN)
Publication Details
- Journal
- Experimental Heat Transfer
- Published
- 2026-11-18
- DOI
- https://doi.org/10.1080/08916152.2026.2763025
- Primary Topic
- Heat Transfer and Optimization
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- National Key Research and Development Program of China