Temperature and frequency dependent electrothermal analysis of coated and uncoated power conductors under non-sinusoidal currents

This article presents a unified analytical and finite-difference electrothermal framework, implemented in Python, for evaluating coated and uncoated copper and aluminum conductors subjected to sinusoidal and Fourier-derived non-sinusoidal currents. The modified current is obtained by full-wave rectification of a sinusoidal function and represented by a truncated Fourier series. The formulation couples temperature-dependent electrical resistivity and conductor geometry with frequency-dependent AC resistance and a skin-effect correction applied to each retained harmonic component. The DC and harmonic Joule losses are calculated separately and used as thermal sources in lumped analytical and one-dimensional distributed models. The convergence analysis showed that N = 11 yields a normalized root-mean-square error (NRMSE) of approximately 0.36%, with negligible thermal variation relative to higher truncation orders. For a 16 mm 2 copper conductor carrying a 130 A peak current at 60 Hz over 2 h, the PVC-like coating reduced the final temperature from approximately 92.21 °C to 60.27 °C, corresponding to a 47.53% reduction in temperature rise above ambient. This reduction follows from the critical radius of insulation and persists for convection coefficients below approximately 60 W m − 2 K − 1 . The sinusoidal and modified currents produced final-temperature differences below 0.003 °C, although their time-domain electric-field responses were markedly different. For a six-pulse rectifier current with the same RMS value and a total harmonic distortion of 29%, the harmonic-resolved losses of the same conductor increased by only 0.07%. Aluminum produced higher temperatures and electric-field amplitudes than copper. The constant-coefficient lumped solution underestimated the mid-length temperature of the distributed model, which includes resistivity feedback, by up to approximately 14 ° C for the uncoated copper conductor, whereas a closed-form fin solution with linear resistivity feedback reproduced the finite-difference integral-mean and mid-length temperatures within 0.05 ° C for the copper cases. Overall, conductor material and coating configuration primarily governed the thermal response, whereas harmonic content mainly affected the time-domain field and frequency-dependent losses.

Authors

Institutions

Publication Details

Journal
International Communications in Heat and Mass Transfer
Published
2026-11-18
DOI
https://doi.org/10.1016/j.icheatmasstransfer.2026.112955
Primary Topic
Thermal Analysis in Power Transmission
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Temperature and frequency dependent electrothermal analysis of coated and uncoated power conductors under non-sinusoidal currents

Marcus V.S. da Silva, Ricardo Augusto de Araújo, José Pissolato Filho, Jaimis S.L. Colqui
2 links
International Communications in Heat and Mass Transfer
Thermal Analysis in Power Transmission
article

Temperature and frequency dependent electrothermal analysis of coated and uncoated power conductors under non-sinusoidal currents

Marcus V.S. da Silva, Ricardo Augusto de Araújo, José Pissolato Filho, Jaimis S.L. Colqui
article en

Abstract

This article presents a unified analytical and finite-difference electrothermal framework, implemented in Python, for evaluating coated and uncoated copper and aluminum conductors subjected to sinusoidal and Fourier-derived non-sinusoidal currents. The modified current is obtained by full-wave rectification of a sinusoidal function and represented by a truncated Fourier series. The formulation couples temperature-dependent electrical resistivity and conductor geometry with frequency-dependent AC resistance and a skin-effect correction applied to each retained harmonic component. The DC and harmonic Joule losses are calculated separately and used as thermal sources in lumped analytical and one-dimensional distributed models. The convergence analysis showed that N = 11 yields a normalized root-mean-square error (NRMSE) of approximately 0.36%, with negligible thermal variation relative to higher truncation orders. For a 16 mm 2 copper conductor carrying a 130 A peak current at 60 Hz over 2 h, the PVC-like coating reduced the final temperature from approximately 92.21 °C to 60.27 °C, corresponding to a 47.53% reduction in temperature rise above ambient. This reduction follows from the critical radius of insulation and persists for convection coefficients below approximately 60 W m − 2 K − 1 . The sinusoidal and modified currents produced final-temperature differences below 0.003 °C, although their time-domain electric-field responses were markedly different. For a six-pulse rectifier current with the same RMS value and a total harmonic distortion of 29%, the harmonic-resolved losses of the same conductor increased by only 0.07%. Aluminum produced higher temperatures and electric-field amplitudes than copper. The constant-coefficient lumped solution underestimated the mid-length temperature of the distributed model, which includes resistivity feedback, by up to approximately 14 ° C for the uncoated copper conductor, whereas a closed-form fin solution with linear resistivity feedback reproduced the finite-difference integral-mean and mid-length temperatures within 0.05 ° C for the copper cases. Overall, conductor material and coating configuration primarily governed the thermal response, whereas harmonic content mainly affected the time-domain field and frequency-dependent losses.

International Communications in Heat and Mass TransferVol. 181
Universidade Federal de Lavras (BR), Universidade Estadual de Campinas (UNICAMP) (BR)
Fundação de Amparo à Pesquisa do Estado de São Paulo
Affordable and clean energy
Thermal Analysis in Power Transmission
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon