Sacroiliac joint hounsfield units as a predictor of postoperative S2AI screw loosening in spinal fusion surgery: a retrospective cohort study

S2-alar-iliac (S2AI) screw fixation provides essential pelvic anchorage in complex spinal fusion. However, screw loosening remains a potential complication, as fixation stability depends partly on local bone quality along the sacral and iliac screw trajectory. Although lumbar vertebral Hounsfield units (HU) measured from routine computed tomography (CT) scan have been investigated as an opportunistic marker of bone quality, the association between sacroiliac (SI) HU and S2AI screw loosening remains unclear. Lower SI HU was hypothesized to be associated with greater odds of S2AI screw loosening. This retrospective cohort study included 98 patients who underwent spinopelvic fixation using S2AI screws between January 2016 and October 2023, with ≥ 12 months of follow-up. Clinical, surgical, and radiographic parameters were collected. SI and L1 vertebral body HU values were measured on preoperative CT. Screw loosening was defined as a radiolucent zone > 1 mm surrounding the screw. Variables with p < 0.1 in univariate analysis or considered clinically relevant were included in multivariate logistic regression to evaluate factors associated with loosening. Radiographic S2AI screw loosening was observed in 36 of 98 patients (36.7%) at the 1-year assessment. The loosening group had significantly lower SI HU values (168.3 ± 60.4 vs. 196.7 ± 64.8, p = 0.003) and shorter screw lengths ( p = 0.013). In multivariate analysis, lower SI HU (adjusted odds ratio [aOR] per HU, 0.989; 95% CI: 0.980–0.997; p = 0.009), shorter screw length (aOR per mm, 0.929; p = 0.034), and higher body mass index(BMI) (aOR per kg/m², 1.140; p = 0.013) were associated with loosening. An exploratory SI HU threshold of ≤ 190 showed modest discrimination (area under curve = 0.636; sensitivity, 51%; specificity, 73%). Lower SI HU, shorter S2AI screw length, and higher BMI were associated with S2AI screw loosening in this retrospective cohort. An SI HU threshold of ≤ 190 may help identify patients with increased odds of loosening but should not be used in isolation. Site-specific bone attenuation may complement implant and patient-related considerations during preoperative assessment; further validation is needed.

Authors

Institutions

Publication Details

Journal
Journal of Orthopaedic Surgery and Research
Published
2026-11-18
DOI
https://doi.org/10.1186/s13018-026-07393-z
Primary Topic
Spinal Fractures and Fixation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Sacroiliac joint hounsfield units as a predictor of postoperative S2AI screw loosening in spinal fusion surgery: a retrospective cohort study

Jung-Chun Chen, Chien‐Lin Liu, Yu‐Cheng Yao, Po‐Hsin Chou et al.
3 links
Journal of Orthopaedic Surgery and Research
Spinal Fractures and Fixation Techniques
article

Sacroiliac joint hounsfield units as a predictor of postoperative S2AI screw loosening in spinal fusion surgery: a retrospective cohort study

Jung-Chun Chen, Chien‐Lin Liu, Yu‐Cheng Yao, Po‐Hsin Chou, Shih-Tien Wang, Hsi-Hsien Lin
article en

Abstract

S2-alar-iliac (S2AI) screw fixation provides essential pelvic anchorage in complex spinal fusion. However, screw loosening remains a potential complication, as fixation stability depends partly on local bone quality along the sacral and iliac screw trajectory. Although lumbar vertebral Hounsfield units (HU) measured from routine computed tomography (CT) scan have been investigated as an opportunistic marker of bone quality, the association between sacroiliac (SI) HU and S2AI screw loosening remains unclear. Lower SI HU was hypothesized to be associated with greater odds of S2AI screw loosening. This retrospective cohort study included 98 patients who underwent spinopelvic fixation using S2AI screws between January 2016 and October 2023, with ≥ 12 months of follow-up. Clinical, surgical, and radiographic parameters were collected. SI and L1 vertebral body HU values were measured on preoperative CT. Screw loosening was defined as a radiolucent zone > 1 mm surrounding the screw. Variables with p < 0.1 in univariate analysis or considered clinically relevant were included in multivariate logistic regression to evaluate factors associated with loosening. Radiographic S2AI screw loosening was observed in 36 of 98 patients (36.7%) at the 1-year assessment. The loosening group had significantly lower SI HU values (168.3 ± 60.4 vs. 196.7 ± 64.8, p = 0.003) and shorter screw lengths ( p = 0.013). In multivariate analysis, lower SI HU (adjusted odds ratio [aOR] per HU, 0.989; 95% CI: 0.980–0.997; p = 0.009), shorter screw length (aOR per mm, 0.929; p = 0.034), and higher body mass index(BMI) (aOR per kg/m², 1.140; p = 0.013) were associated with loosening. An exploratory SI HU threshold of ≤ 190 showed modest discrimination (area under curve = 0.636; sensitivity, 51%; specificity, 73%). Lower SI HU, shorter S2AI screw length, and higher BMI were associated with S2AI screw loosening in this retrospective cohort. An SI HU threshold of ≤ 190 may help identify patients with increased odds of loosening but should not be used in isolation. Site-specific bone attenuation may complement implant and patient-related considerations during preoperative assessment; further validation is needed.

Journal of Orthopaedic Surgery and Research
National Yang Ming Chiao Tung University (TW), Taipei Veterans General Hospital (TW)
Good health and well-being
Spinal Fractures and Fixation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon