PSO-Calibrated Fuzzy Adaptive PID Control for Deviation Suppression of a Tracked Pipeline Inspection Robot

Background: Tracked inspection robots in large-diameter pipelines are vulnerable to unequal track adhesion, drive mismatch, slip, speed variation, and payload-induced disturbances, which accumulate into yaw and lateral deviation. Methods: A dual-loop architecture was developed in which an outer path-attraction loop generates a bounded desired heading and an inner heading loop uses a fuzzy adaptive proportional–integral–derivative (PID) controller calibrated offline by particle swarm optimization (PSO). The calibration jointly searches baseline PID gains, fuzzy scaling factors, and small-error freezing thresholds. Derivative filtering, differential-speed saturation, and back-calculation anti-windup were incorporated. Validation comprised random multi-scenario simulations, encoder and inertial measurement unit (IMU) calibration, and 72 physical trials spanning two robot configurations, three speeds, and four control methods. Results: The proposed method achieved a mean post-disturbance root-mean-square lateral-error of 0.00586 m, an engineering settling time of 2.35 s, and a control total variation of 0.663, improving these metrics by 17.2%, 26.9%, and 87.4%, respectively, relative to engineering PID. Relative to fixed PSO–PID, it reduced integral of time-weighted absolute error (ITAE) and quadratic differential-speed command cost but accepted small increases in peak error, engineering settling time, and command variation. In descriptive within-protocol physical comparisons, the reconstructed maximum lateral deviation was reduced by 76.3–91.2% relative to uncompensated motion. Conclusions: Offline global calibration and online local adaptation provide a balanced error–command–cost–smoothness compromise and improve deviation suppression over engineering PID across the tested simulation conditions. The physical evidence remains descriptive because lateral deviation was reconstructed rather than directly measured by an independent positioning system.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2026-11-18
DOI
https://doi.org/10.3390/app162211421
Primary Topic
Control and Dynamics of Mobile Robots
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

PSO-Calibrated Fuzzy Adaptive PID Control for Deviation Suppression of a Tracked Pipeline Inspection Robot

Lei Yan, Xufeng Cheng, W CHEN, Yilun Liu et al.
2 links
Applied Sciences
Control and Dynamics of Mobile Robots
article

PSO-Calibrated Fuzzy Adaptive PID Control for Deviation Suppression of a Tracked Pipeline Inspection Robot

Lei Yan, Xufeng Cheng, W CHEN, Yilun Liu, Min Luo, Jiacai Zhang
article en

Abstract

Background: Tracked inspection robots in large-diameter pipelines are vulnerable to unequal track adhesion, drive mismatch, slip, speed variation, and payload-induced disturbances, which accumulate into yaw and lateral deviation. Methods: A dual-loop architecture was developed in which an outer path-attraction loop generates a bounded desired heading and an inner heading loop uses a fuzzy adaptive proportional–integral–derivative (PID) controller calibrated offline by particle swarm optimization (PSO). The calibration jointly searches baseline PID gains, fuzzy scaling factors, and small-error freezing thresholds. Derivative filtering, differential-speed saturation, and back-calculation anti-windup were incorporated. Validation comprised random multi-scenario simulations, encoder and inertial measurement unit (IMU) calibration, and 72 physical trials spanning two robot configurations, three speeds, and four control methods. Results: The proposed method achieved a mean post-disturbance root-mean-square lateral-error of 0.00586 m, an engineering settling time of 2.35 s, and a control total variation of 0.663, improving these metrics by 17.2%, 26.9%, and 87.4%, respectively, relative to engineering PID. Relative to fixed PSO–PID, it reduced integral of time-weighted absolute error (ITAE) and quadratic differential-speed command cost but accepted small increases in peak error, engineering settling time, and command variation. In descriptive within-protocol physical comparisons, the reconstructed maximum lateral deviation was reduced by 76.3–91.2% relative to uncompensated motion. Conclusions: Offline global calibration and online local adaptation provide a balanced error–command–cost–smoothness compromise and improve deviation suppression over engineering PID across the tested simulation conditions. The physical evidence remains descriptive because lateral deviation was reconstructed rather than directly measured by an independent positioning system.

Applied SciencesVol. 16(22)
Beijing Forestry University (CN), Weifang University (CN)
Industry, innovation and infrastructure
Control and Dynamics of Mobile Robots
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon