Ideal gas Law Based assessment of Gas Generation and Pressure Raise in Industrial Scale
The industrial-scale handling of azide compounds presents severe process safety challenges due to the rapid generation of highly volatile, toxic, and potentially explosive hydrazoic acid HN3 Gas. This paper establishes a rigorous chemical engineering framework for the design and sizing of an emergency relief venting system during a batch reactor emission event involving triethylammonium chloride and sodium azide. Stoichiometric mass balance evaluation identifies sodium azide as the strictly limiting reactant, limiting the maximum theoretical yield of volatile HN3 to 1.107 kmol (47.62 kg). showing that a critical density drops to 1.42 Kg/m3 at elevated temperatures dictates the maximum volumetric displacement. By constraining the maximum allowable relief velocity to 15 m/s to limit backpressure, fluid-dynamic sizing formulations were utilized to determine the minimum cross-sectional area. The engineering analysis demonstrates that a 4-inch nominal diameter vent line is required to safely discharge the peak volumetric flow without risking vessel over pressurization. This study provides a scalable, standardized baseline for loss prevention and safety relief design in hazardous azide-based batch manufacturing operations.
Authors
- Ravindra Chitturi
- Srikanth Reddy Jonnala
- Jagadeeshwarao Bora
- Ranjith Kumar Patnala
- Srinivas Satti
- Naidu Dwarapureddi
- Mahesh Bevera
Institutions
- Andhra University (IN)
Publication Details
- Journal
- Zenodo (CERN European Organization for Nuclear Research)
- Published
- 2026-11-18
- DOI
- https://doi.org/10.5281/zenodo.24333218
- Primary Topic
- Risk and Safety Analysis
- Type
- article
- Field-Weighted Citation Impact
- 0.00