Vibration Diagnosis of a Compound Bearing Fault in a Locomotive Traction Fan Motor Based on Dismantling-Verified Ground Truth and a Data-Integrity Audit

A HXD1C locomotive traction fan motor with excessive vibration under rated speed is diagnosed from front-and rear-end return-test records against dismantling-verified findings: the front-end bearing showed grease leakage, carbonization and stiff rotation (wear), while the rear-end outer ring suffered severe creep (fretting) corrosion yet rotated freely. Because segment gains were inconsistent, a data-integrity audit was performed first; time-domain indices, shaft-frequencynormalized spectra and resonant envelope spectra were then computed only on clean, unclipped segments and compared with theoretical 6310 frequencies. High-gain segments showed positive-direction clipping near full scale, inflating the apparent rear-end kurtosis to 38-67; after excluding them, clean-segment kurtosis dropped to 3.0-3.8, showing the apparent impulsiveness to be an acquisition artifact. Front-end clean segments were energetic and rich in low-order shaft harmonics, matching distributed lubrication/wear damage, whereas rear-end clean segments were flat broadband random vibration with no shaft-harmonic or bearing pass-frequency chain. The 6310 outer-race, inner-race and rolling-element frequencies lie within 0.9-1.6 Hz of the 3rd, 5th and 2nd shaft harmonics-indistinguishable at 1 s/1 Hz resolution-and, combined with non-impulsive creep, make the rear-end damage easily missed by conventional envelope analysis. The case exposes two field pitfalls (range-limited kurtosis artifacts; faultfrequency/shaft-harmonic coincidence) and motivates range headroom, clipping quality gates, longer records with a keyphasor or tacholess order tracking. Conclusions are limited to a single unit under one operating condition.

Authors

Institutions

Publication Details

Journal
Engineering Research Express
Published
2026-11-18
DOI
https://doi.org/10.1088/2631-8695/aec414
Primary Topic
Machine Fault Diagnosis Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Vibration Diagnosis of a Compound Bearing Fault in a Locomotive Traction Fan Motor Based on Dismantling-Verified Ground Truth and a Data-Integrity Audit

Xueming Luo, Jianghong Yu, Shuai Ye
Engineering Research Express
Machine Fault Diagnosis Techniques
article

Vibration Diagnosis of a Compound Bearing Fault in a Locomotive Traction Fan Motor Based on Dismantling-Verified Ground Truth and a Data-Integrity Audit

Xueming Luo, Jianghong Yu, Shuai Ye
article en

Abstract

A HXD1C locomotive traction fan motor with excessive vibration under rated speed is diagnosed from front-and rear-end return-test records against dismantling-verified findings: the front-end bearing showed grease leakage, carbonization and stiff rotation (wear), while the rear-end outer ring suffered severe creep (fretting) corrosion yet rotated freely. Because segment gains were inconsistent, a data-integrity audit was performed first; time-domain indices, shaft-frequencynormalized spectra and resonant envelope spectra were then computed only on clean, unclipped segments and compared with theoretical 6310 frequencies. High-gain segments showed positive-direction clipping near full scale, inflating the apparent rear-end kurtosis to 38-67; after excluding them, clean-segment kurtosis dropped to 3.0-3.8, showing the apparent impulsiveness to be an acquisition artifact. Front-end clean segments were energetic and rich in low-order shaft harmonics, matching distributed lubrication/wear damage, whereas rear-end clean segments were flat broadband random vibration with no shaft-harmonic or bearing pass-frequency chain. The 6310 outer-race, inner-race and rolling-element frequencies lie within 0.9-1.6 Hz of the 3rd, 5th and 2nd shaft harmonics-indistinguishable at 1 s/1 Hz resolution-and, combined with non-impulsive creep, make the rear-end damage easily missed by conventional envelope analysis. The case exposes two field pitfalls (range-limited kurtosis artifacts; faultfrequency/shaft-harmonic coincidence) and motivates range headroom, clipping quality gates, longer records with a keyphasor or tacholess order tracking. Conclusions are limited to a single unit under one operating condition.

Engineering Research Express
Hunan University of Technology (CN)
Natural Science Foundation of Hunan Province
Machine Fault Diagnosis Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon