Frequency and Patient Throughput Characteristics of Implanted Cardiac Device Interrogation in the Emergency Department
OBJECTIVES: Patients with cardiac implantable electronic devices (CIEDs), such as pacemakers and implantable cardioverter-defibrillators, frequently present to the emergency department (ED) with complaints potentially attributable to their devices. Device interrogation can characterize arrhythmias and guide management, but whether it represents a bottleneck to disposition has not been systematically studied. METHODS: Retrospective cohort study at two academic centers (2024-2026). Visits were identified via consultations. Control cohorts of patients with general cardiology and EP consultations with pacemakers were propensity score matched. Intervals were compared via Kruskal-Wallis tests. Logistic regression investigated associations between demographic factors, time intervals, and admission. RESULTS: We identified 677 visits from 479 unique patients involving CIED-related EP consultation. The median ED length of stay (LOS) was 24.3 hours (IQR 10.2-36.1), with 80.4% admitted. General cardiology and EP consults without interrogation demonstrated similar times to consultation (4.0 [IQR 1.8-11.1] and 3.0 [IQR 0.9-12.4], p=0.4 and p=0.1), but shorter from consult to disposition (13.3 hours [IQR 12.7-14.4] vs. 5.2 [IQR 4.5-5.9] and 6.8 [IQR 6.0-7.5], both p<0.001). Consults with interrogation after hours were prolonged (14.9 [IQR 7.1-20.5] vs 7.1 [IQR 5.4-11.1], p<0.001). In the logistic regression, longer consultations were associated with higher likelihood of admission (aOR 1.05, 95% CI 1.02-1.07 per hour). No other factors were significant. CONCLUSION: Patients requiring CIED interrogation experienced delays relative to other patients, with interrogation as the proximate step before disposition. Consults after hours took longer, and delays were independently associated with admission. These findings highlight an operational bottleneck in acute CIED management, and efforts to expedite device interrogation warrant further investigation.
Authors
- James F. Neuenschwander
- Thomas M. Tadros (ORCID: https://orcid.org/0000-0002-2397-038X)
- Joshua W. Joseph (ORCID: https://orcid.org/0000-0001-9704-6635)
- Maxwell Douglas Coll (ORCID: https://orcid.org/0000-0002-2507-7587)
- Abd Al-Rahman Traboulsi (ORCID: https://orcid.org/0000-0002-4227-7863)
- Matthew R. Carey (ORCID: https://orcid.org/0000-0002-5838-8437)
- Christopher W. Baugh (ORCID: https://orcid.org/0000-0002-2360-1891)
Institutions
- Brigham and Women's Hospital (US)
- Massachusetts General Hospital (US)
- Harvard Affiliated Emergency Medicine Residency (US)
- The Ohio State University (US)
Publication Details
- Journal
- Critical Pathways in Cardiology A Journal of Evidence-Based Medicine
- Published
- 2026-11-18
- DOI
- https://doi.org/10.1097/hpc.0000000000000442
- Primary Topic
- Emergency and Acute Care Studies
- Type
- article
- Field-Weighted Citation Impact
- 0.00