Sample-Handling Bias and Direct ICP-MS of Ultratrace Metals in Semiconductor-Grade Isopropyl Alcohol

Sample handling can materially affect the reliability of ultratrace elemental analysis even when instrumental precision is adequate. Here, storage-container behavior and a conventional evaporation-to-apparent-dryness/acid-reconstitution procedure were evaluated for metal determination in semiconductor-grade isopropyl alcohol (IPA) by inductively coupled plasma mass spectrometry (ICP-MS). Perfluoroalkoxy alkane (PFA) provided the most stable performance among the tested storage and evaporation vessels, whereas Cr and Sn exhibited reduced recoveries even under room-temperature evaporation conditions. Sequential acid extraction of polytetrafluoroethylene (PTFE) vessels further revealed incomplete initial recovery and delayed analyte release, consistent with surface-associated retention. To minimize these handling-related effects, a direct matrix-matched standard-addition workflow combining desolvation with oxygen-assisted plasma stabilization was evaluated. Relative to direct analysis without desolvation, the optimized configuration reduced calibration-derived background-equivalent concentrations from 0.25–11.48 to 0.04–5.02 ng kg–1 and increased calibration sensitivity by 4.46–9.21-fold (R2 = 0.9998–1.0000). An existing low-level replicate data set at a 20 ng kg–1 addition level (n = 7), originally acquired for LOD/LOQ evaluation, gave BEC-corrected recoveries of 95.06–104.23% with RSDs of 0.90–5.81%; targeted verification at 100 ng kg–1 (n = 7) gave recoveries of 96.54–102.33% with RSDs ≤3.50%. LODs were 0.77–7.39 ng kg–1. These results show that sample-handling effects should be evaluated alongside instrumental performance when ultratrace impurities are measured in high-purity organic process chemicals. The contribution of this study lies in linking experimentally observed handling-related recovery behavior with a preparation-minimizing analytical workflow rather than in introducing a new desolvation configuration.

Authors

Institutions

Publication Details

Journal
ACS Omega
Published
2026-11-18
DOI
https://doi.org/10.1021/acsomega.6c09552
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Sample-Handling Bias and Direct ICP-MS of Ultratrace Metals in Semiconductor-Grade Isopropyl Alcohol

Dongchul Suh, Seongkyong Joo, Soyeon Yun
ACS Omega
Analytical chemistry methods development
article

Sample-Handling Bias and Direct ICP-MS of Ultratrace Metals in Semiconductor-Grade Isopropyl Alcohol

Dongchul Suh, Seongkyong Joo, Soyeon Yun
article en

Abstract

Sample handling can materially affect the reliability of ultratrace elemental analysis even when instrumental precision is adequate. Here, storage-container behavior and a conventional evaporation-to-apparent-dryness/acid-reconstitution procedure were evaluated for metal determination in semiconductor-grade isopropyl alcohol (IPA) by inductively coupled plasma mass spectrometry (ICP-MS). Perfluoroalkoxy alkane (PFA) provided the most stable performance among the tested storage and evaporation vessels, whereas Cr and Sn exhibited reduced recoveries even under room-temperature evaporation conditions. Sequential acid extraction of polytetrafluoroethylene (PTFE) vessels further revealed incomplete initial recovery and delayed analyte release, consistent with surface-associated retention. To minimize these handling-related effects, a direct matrix-matched standard-addition workflow combining desolvation with oxygen-assisted plasma stabilization was evaluated. Relative to direct analysis without desolvation, the optimized configuration reduced calibration-derived background-equivalent concentrations from 0.25–11.48 to 0.04–5.02 ng kg–1 and increased calibration sensitivity by 4.46–9.21-fold (R2 = 0.9998–1.0000). An existing low-level replicate data set at a 20 ng kg–1 addition level (n = 7), originally acquired for LOD/LOQ evaluation, gave BEC-corrected recoveries of 95.06–104.23% with RSDs of 0.90–5.81%; targeted verification at 100 ng kg–1 (n = 7) gave recoveries of 96.54–102.33% with RSDs ≤3.50%. LODs were 0.77–7.39 ng kg–1. These results show that sample-handling effects should be evaluated alongside instrumental performance when ultratrace impurities are measured in high-purity organic process chemicals. The contribution of this study lies in linking experimentally observed handling-related recovery behavior with a preparation-minimizing analytical workflow rather than in introducing a new desolvation configuration.

ACS Omega
Hoseo University (KR)
Hoseo University, Korea Institute of Energy Technology Evaluation and Planning
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon