Evaluation of wedge-induced photoneutron dose during 15 MV 3D conformal rectal radiotherapy using TLD600/TLD700 pairs

BackgroundLinear accelerators are widely used in radiotherapy. However, photoneutron production may occur during high energy photon radiotherapy. Neutrons have a high radiation weighting factor.PurposeTo compare the thermal neutron sensitive TLD responses with and without wedge use during simulated rectal radiotherapy using TLD600/700 pairs.MethodsTLD pairs were placed in the target (rectal region), bladder, and right femur regions of an anthropomorphic Rando phantom for simulated rectal radiotherapy. Computed tomography images were acquired and transferred to the Prowess treatment planning system (TPS). Wedge and non-wedge plans were created using 15 MV photons at a treatment dose of 2 Gy. Plans were delivered using a Siemens Artiste™ linear accelerator. TLDs were read using a Harshaw system, and Am-Be calibrated neutron sensitive responses were expressed in mSv/Gy. Wedge/non-wedge response ratios were also calculated.ResultsAm-Be calibrated values for wedge versus non-wedge plans were 0.37 vs. 0.19 mSv/Gy for the target, 0.43 vs. 0.17 mSv/Gy for the bladder, and 0.51 vs. 0.22 mSv/Gy for the right femur, corresponding to wedge/non-wedge ratios of 1.95, 2.53, and 2.32, respectively.ConclusionsNeutron sensitive TLD responses were higher for the wedge plan than for the non-wedge plan at the same measurement positions.

Authors

Institutions

Publication Details

Journal
Journal of X-Ray Science and Technology
Published
2026-11-18
DOI
https://doi.org/10.1177/08953996261509409
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Evaluation of wedge-induced photoneutron dose during 15 MV 3D conformal rectal radiotherapy using TLD600/TLD700 pairs

Osman Vefa Gül, Nurhak Tatar, R. Yılmaz, Hikmettin Demir et al.
Journal of X-Ray Science and Technology
Advanced Radiotherapy Techniques
article

Evaluation of wedge-induced photoneutron dose during 15 MV 3D conformal rectal radiotherapy using TLD600/TLD700 pairs

Osman Vefa Gül, Nurhak Tatar, R. Yılmaz, Hikmettin Demir, Tahir Çakır
article en

Abstract

BackgroundLinear accelerators are widely used in radiotherapy. However, photoneutron production may occur during high energy photon radiotherapy. Neutrons have a high radiation weighting factor.PurposeTo compare the thermal neutron sensitive TLD responses with and without wedge use during simulated rectal radiotherapy using TLD600/700 pairs.MethodsTLD pairs were placed in the target (rectal region), bladder, and right femur regions of an anthropomorphic Rando phantom for simulated rectal radiotherapy. Computed tomography images were acquired and transferred to the Prowess treatment planning system (TPS). Wedge and non-wedge plans were created using 15 MV photons at a treatment dose of 2 Gy. Plans were delivered using a Siemens Artiste™ linear accelerator. TLDs were read using a Harshaw system, and Am-Be calibrated neutron sensitive responses were expressed in mSv/Gy. Wedge/non-wedge response ratios were also calculated.ResultsAm-Be calibrated values for wedge versus non-wedge plans were 0.37 vs. 0.19 mSv/Gy for the target, 0.43 vs. 0.17 mSv/Gy for the bladder, and 0.51 vs. 0.22 mSv/Gy for the right femur, corresponding to wedge/non-wedge ratios of 1.95, 2.53, and 2.32, respectively.ConclusionsNeutron sensitive TLD responses were higher for the wedge plan than for the non-wedge plan at the same measurement positions.

Journal of X-Ray Science and Technology
Van Yüzüncü Yıl Üniversitesi (TR), Selçuk University (TR), Hacettepe University (TR)
Bilimsel Araştırma Projeleri Koordinasyon Birimi, Yüzüncü Yil Üniversitesi
Good health and well-being
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon