Evaluation of the Metal Artifact Caused by Two Different Amalgams in Cone Beam Computed Tomography Images
Background The aim of this study was to evaluate and compare the intensity of the artifacts produced by two different types of dental amalgam restorations using two cone-beam computed tomography (CBCT) unite. Methods For this experimental study, three dry human mandibles were selected. Two different types of amalgam (A: high-silver B: low-silver) were prepared in standardized dimensions of 8*8*8 mm and placed in the empty sockets of lateral incisor and first molar teeth were stabilized using dental wax. Each mandible was placed in the phantom simulating soft tissue and occlusal plane was adjusted parallel to the horizontal plane. The CBCT images were taken with two different CBCT devices and two different resolutions. Gray values and the contrast noise ratio (CNR) was calculated. The CNR values of images were analyzed based on the amalgam type, image resolution, jaw region (anterior vs posterior), units parameters, and the results were statistically analyzed using the paired t-test. Results Depending on the CBCT device, the CNR values for A and B amalgams are completely different. The CNR values of both amalgam types were significantly higher under high resolution settings compared to standard resolution. However, no significant difference in CNR values were observed between the anterior and posterior regions of the mandible. Conclusions The extent of metal artifacts in CBCT images is significantly influenced by the type of amalgam, scanning parameters, and image resolution. Higher resolution led to an increase in CNR (p-value = 0.000). However, the location of the amalgam (anterior or posterior regions of the mandible) had no significant effect on the artifact level. These findings can contribute to improving CBCT image quality in the presence of metallic restorations.
Authors
- Homayoon Alaghehmand (ORCID: https://orcid.org/0000-0003-4531-3994)
- Sina Haghanifar (ORCID: https://orcid.org/0000-0001-5949-8913)
- Maryam Johari (ORCID: https://orcid.org/0000-0002-1792-2971)
- Ali Bijani (ORCID: https://orcid.org/0000-0003-2233-8726)
- Ehsan Moudi (ORCID: https://orcid.org/0000-0001-7226-5305)
- Ariana Rezaei Majd (ORCID: https://orcid.org/0009-0002-7677-6481)
- Atena Jamali
Institutions
- Babol University of Medical Sciences (IR)
Publication Details
- Journal
- Research Square
- Published
- 2026-11-18
- DOI
- https://doi.org/10.21203/rs.3.rs-11254634/v1
- Primary Topic
- Dental Radiography and Imaging
- Type
- preprint