High Prevalence of Multidrug-resistant Gram-negative Bacteria on Neonatal Intensive Care Unit Surfaces at a Tertiary Hospital in Kampala, Uganda
BACKGROUND: About 60% of neonatal sepsis cases are hospital-acquired and are often caused by Gram-negative bacteria, with a high rate of antimicrobial resistance. Outbreaks of multidrug-resistant bacteria in neonatal units occur at rates 20 times higher in low- and middle-income countries than in high-income settings. We conducted 4 rounds (R1-4) of environmental sampling in a neonatal intensive care unit (NICU) in Kampala, Uganda, to inform an infection prevention and control (IPC) program tailored to a resource-limited setting. METHODS: Eighty-two swabs were taken over 12 months (2021-2022) from n = 13 high-touch surfaces, n = 10 low-touch surfaces (R1-3) and n = 6 staff items (R4). Potential pathogens were identified using standard biochemical methods. Antimicrobial susceptibility testing was performed using Kirby-Bauer disk diffusion. Hand hygiene audits were conducted throughout the study period. A collaborative working group of NICU, IPC and research staff co-developed IPC interventions. RESULTS: Of 146 organisms isolated, 127 (82%) were potential pathogens, predominantly Pseudomonas spp., Acinetobacter spp. and Citrobacter spp. High-touch sites such as sinks, cots and drug trolleys showed persistent contamination. Resistance to first-line antibiotics was high: gentamicin (48/91, 52%), ampicillin (25/25, 100%) and ceftazidime (30/91, 33%). After color-coded feedback, a unit-wide deep clean reduced potential pathogens by 60% from R1 (n = 63) to R2 (n = 25). However, levels rebounded in R3 (n = 32), representing a 21% increase compared with R2 (n = 25), highlighting inconsistencies in cleaning. CONCLUSIONS: Targeted environmental cleaning can reduce NICU contamination by multidrug-resistant Gram-negative bacterial pathogens. Sinks were persistent reservoirs, underscoring the need for consistent daily cleaning and staff engagement. In low- and middle-income country settings, simple, low-cost IPC measures informed by environmental surveillance may support sustainable hospital-acquired infection reduction.
Authors
- Hannah Georgia Davies (ORCID: https://orcid.org/0000-0002-9064-0874)
- Mary Kyohere (ORCID: https://orcid.org/0009-0003-1180-6333)
- Henry Kajumbula (ORCID: https://orcid.org/0000-0002-2075-0007)
- Lauren Hookham (ORCID: https://orcid.org/0000-0001-9703-655X)
- Kirsty Le Doaré (ORCID: https://orcid.org/0000-0002-5104-085X)
- Musa Sekikubo (ORCID: https://orcid.org/0000-0002-7335-9650)
- Amusa Wamawobe (ORCID: https://orcid.org/0000-0001-7503-6778)
- Philippa Musoke
- Loy Nabirye
- Pauline Nanfuka
- Maimuna Namazzi
Institutions
- Brighton and Sussex Medical School (GB)
- University of Sussex (GB)
- St George's, University of London (GB)
- City, University of London (GB)
- Liverpool School of Tropical Medicine (GB)
- Malawi-Liverpool-Wellcome Trust Clinical Research Programme (MW)
- London School of Hygiene & Tropical Medicine (GB)
- Hospital for Tropical Diseases (GB)
- MUJHU Research Collaboration (UG)
- City St George's, University of London (GB)
- Makerere University (UG)
Publication Details
- Journal
- The Pediatric Infectious Disease Journal
- Published
- 2026-11-18
- DOI
- https://doi.org/10.1097/inf.0000000000005449
- Primary Topic
- Infection Control in Healthcare
- Type
- article
- Field-Weighted Citation Impact
- 0.00