BATTERY MANAGEMENT SYSTEM (BMS) USING ARDUINO UNO FOR BATTERY PROTECTION

Rechargeable lithium-ion batteries now power electric two-wheelers, solar storage units, uninterruptible power supplies, and a wide range of portable equipment. These batteries offer high energy density but are sensitive to overcharge, deep discharge, excessive current, and high temperature, any of which can shorten their life or, in the worst case, lead to swelling, fire, or thermal runaway. Many low-cost battery packs used in student projects and small vehicles have only minimal protection and give the user no information about the condition of the cells. This paper presents a Battery Management System using an Arduino UNO that monitors a series lithium-ion pack, protects it against unsafe conditions, balances the cells, and reports its state to the user. The prototype is built for a four-cell series pack of 18650 lithium-ion cells with a nominal voltage of 14.8 V. Individual cell voltages are measured through precision resistor dividers and an ADS1115 16-bit analog-to-digital converter, pack current is measured with an INA219 sensor over a low-value shunt, and cell temperatures are measured with NTC thermistors attached to the cells. The Arduino UNO processes these readings and controls a pair of back-to-back MOSFETs that disconnect the charger or the load when a limit is exceeded. Protection functions include cell over-voltage cut-off at 4.20 V, cell under-voltage cut-off at 3.00 V, over-current and short circuit protection during discharge, charge current limiting, and over-temperature and under-temperature cut-off. Passive cell balancing is performed by switching bleed resistors across cells whose voltage is higher than the lowest cell by more than a set margin during the final stage of charging. State of charge is estimated by coulomb counting corrected with the open circuit voltage when the pack is at rest, and state of health is estimated from the measured capacity compared with the rated value. Pack data, including cell voltages, current, temperature, state of charge, and fault history, is displayed on an OLED screen and sent through an ESP8266 Wi-Fi module to a cloud dashboard. The user receives alerts when a protection event occurs, when the state of charge falls below a set level, or when a cell shows abnormal behaviour such as faster self-discharge than the others.

Authors

Publication Details

Journal
International Journal of AI Electrical Civil and Mechanical engineering
Published
2026-11-17
DOI
https://doi.org/10.64751/779d2239
Primary Topic
Battery Modeling and Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

BATTERY MANAGEMENT SYSTEM (BMS) USING ARDUINO UNO FOR BATTERY PROTECTION

N. Ganesh, CH. Anand, B. Vikas Reddy, M. Sushanth et al.
International Journal of AI Electrical Civil and Mechanical engineering
Battery Modeling and Management
article

BATTERY MANAGEMENT SYSTEM (BMS) USING ARDUINO UNO FOR BATTERY PROTECTION

N. Ganesh, CH. Anand, B. Vikas Reddy, M. Sushanth, G. Mallikarjun
article en

Abstract

Rechargeable lithium-ion batteries now power electric two-wheelers, solar storage units, uninterruptible power supplies, and a wide range of portable equipment. These batteries offer high energy density but are sensitive to overcharge, deep discharge, excessive current, and high temperature, any of which can shorten their life or, in the worst case, lead to swelling, fire, or thermal runaway. Many low-cost battery packs used in student projects and small vehicles have only minimal protection and give the user no information about the condition of the cells. This paper presents a Battery Management System using an Arduino UNO that monitors a series lithium-ion pack, protects it against unsafe conditions, balances the cells, and reports its state to the user. The prototype is built for a four-cell series pack of 18650 lithium-ion cells with a nominal voltage of 14.8 V. Individual cell voltages are measured through precision resistor dividers and an ADS1115 16-bit analog-to-digital converter, pack current is measured with an INA219 sensor over a low-value shunt, and cell temperatures are measured with NTC thermistors attached to the cells. The Arduino UNO processes these readings and controls a pair of back-to-back MOSFETs that disconnect the charger or the load when a limit is exceeded. Protection functions include cell over-voltage cut-off at 4.20 V, cell under-voltage cut-off at 3.00 V, over-current and short circuit protection during discharge, charge current limiting, and over-temperature and under-temperature cut-off. Passive cell balancing is performed by switching bleed resistors across cells whose voltage is higher than the lowest cell by more than a set margin during the final stage of charging. State of charge is estimated by coulomb counting corrected with the open circuit voltage when the pack is at rest, and state of health is estimated from the measured capacity compared with the rated value. Pack data, including cell voltages, current, temperature, state of charge, and fault history, is displayed on an OLED screen and sent through an ESP8266 Wi-Fi module to a cloud dashboard. The user receives alerts when a protection event occurs, when the state of charge falls below a set level, or when a cell shows abnormal behaviour such as faster self-discharge than the others.

International Journal of AI Electrical Civil and Mechanical engineering
Battery Modeling and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon