Peroxidase-immobilized polycaprolactone/poly(ethylene glycol) diglycidyl ether electrospun nanofibers for colorimetric detection of hydrogen peroxide in seawater

Hydrogen peroxide (H 2 O 2 ) is a key reactive oxygen species in marine systems, serving as an indicator of photochemical activity, organic matter transformation and environmental stress. Its determination in seawater is therefore relevant for assessing water quality, tracking pollution and understanding the biogeochemical processes that influence marine ecosystem health. In this study, nanofibers (NFs) were fabricated from poly-ε-caprolactone (PCL) and poly(ethylene glycol) diglycidyl ether (PEGDE) by electrospinning. Horseradish peroxidase (HRP) was subsequently immobilized onto the surface of the PCL–PEGDE NFs through the epoxy groups of PEGDE. PEGDE served both as a second polymer that renders the nanofiber surface hydrophilic and as a crosslinking agent, allowing the enzyme to be attached in a single step without an additional activation reagent and contributing to the structural integrity of the NFs. The resulting PCL–PEGDE/HRP NFs were used as a spot-test platform for the detection of H 2 O 2 , with 2,2′-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS) as the chromogenic co-substrate. The colour developed on the spot was photographed with a mobile phone and quantified in ImageJ. The response was linear between 0.05 and 1.0 mM H 2 O 2 , and the limit of detection was calculated as 0.004 mM. Applicability in a real matrix was assessed by spike–recovery analysis of seawater collected from İzmir Bay and the Seferihisar Bay, together with tap and bottled water, giving recoveries of 94–104%. The one-step, epoxy-mediated immobilization of HRP on electrospun PCL–PEGDE, and its use as an instrument-free spot test, are the principal contributions of this work, which offers a simple and low-cost format for the preliminary screening of H 2 O 2 in marine water samples.

Authors

Institutions

Publication Details

Journal
Discover Chemistry.
Published
2026-11-18
DOI
https://doi.org/10.1007/s44371-026-01089-3
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Peroxidase-immobilized polycaprolactone/poly(ethylene glycol) diglycidyl ether electrospun nanofibers for colorimetric detection of hydrogen peroxide in seawater

Dilek Odacı Demirkol, Nur Melis Kilic
1 links
Discover Chemistry.
Electrochemical sensors and biosensors
article

Peroxidase-immobilized polycaprolactone/poly(ethylene glycol) diglycidyl ether electrospun nanofibers for colorimetric detection of hydrogen peroxide in seawater

Dilek Odacı Demirkol, Nur Melis Kilic
article en

Abstract

Hydrogen peroxide (H 2 O 2 ) is a key reactive oxygen species in marine systems, serving as an indicator of photochemical activity, organic matter transformation and environmental stress. Its determination in seawater is therefore relevant for assessing water quality, tracking pollution and understanding the biogeochemical processes that influence marine ecosystem health. In this study, nanofibers (NFs) were fabricated from poly-ε-caprolactone (PCL) and poly(ethylene glycol) diglycidyl ether (PEGDE) by electrospinning. Horseradish peroxidase (HRP) was subsequently immobilized onto the surface of the PCL–PEGDE NFs through the epoxy groups of PEGDE. PEGDE served both as a second polymer that renders the nanofiber surface hydrophilic and as a crosslinking agent, allowing the enzyme to be attached in a single step without an additional activation reagent and contributing to the structural integrity of the NFs. The resulting PCL–PEGDE/HRP NFs were used as a spot-test platform for the detection of H 2 O 2 , with 2,2′-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS) as the chromogenic co-substrate. The colour developed on the spot was photographed with a mobile phone and quantified in ImageJ. The response was linear between 0.05 and 1.0 mM H 2 O 2 , and the limit of detection was calculated as 0.004 mM. Applicability in a real matrix was assessed by spike–recovery analysis of seawater collected from İzmir Bay and the Seferihisar Bay, together with tap and bottled water, giving recoveries of 94–104%. The one-step, epoxy-mediated immobilization of HRP on electrospun PCL–PEGDE, and its use as an instrument-free spot test, are the principal contributions of this work, which offers a simple and low-cost format for the preliminary screening of H 2 O 2 in marine water samples.

Discover Chemistry.Vol. 3(1)
Ege University (TR)
Türkiye Bilimsel ve Teknolojik Araştırma Kurumu
Life below water, Clean water and sanitation
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon