Validation of Aquifer Zones Derived from ADMT Interpretation Based on Well Drilling in Jimbaran, Bali

This study was motivated by the importance of groundwater exploration in carbonate rocks in the USDI area of Udayana University, Jimbaran, Bali. Its primary focus is to evaluate the degree of agreement between the results of Audio Magnetotelluric (ADMT) geophysical interpretation and actual subsurface conditions obtained from well drilling. ADMT measurements were conducted at track positions X = 0, 2, 4, 6, 8, and 10 m at depths ranging from 10 to 200 m, with 10-meter intervals. On the X = 4 m profile, resistivity values of 12.11–12.57 Ωm were recorded at depths of 20–60 m, which then decreased significantly to 7.62 Ωm at a depth of 70 m and 7.77 Ωm at a depth of 80 m. The accuracy of the ADMT interpretation was validated in the field when water was first encountered at a depth of 70 m. Drilling continued to a depth of 80 m, confirming that the 70–80 m interval is a verified aquifer zone. Subsequently, a submersible pump was installed at a depth of 75 m. Although the aquifer zone has been validated, the pump’s position at a depth of 75 m leaves a 5-meter gap to the bottom of the well and is very close to the water inflow zone. This makes operational performance vulnerable to dynamic water levels, drawdown, submergence, well development, and potential sediment content. Additionally, conductive anomalies at depths greater than 80 m cannot yet be confirmed as an aquifer because they have not been drilled. To ensure the well’s hydraulic efficiency and feasibility, the study recommends conducting a step-drawdown test, a constant-rate pumping test, and a recovery test, accompanied by periodic monitoring of EC/TDS values and turbidity to determine a safe water withdrawal rate.

Authors

Publication Details

Journal
HAL
Published
2026-11-17
DOI
https://doi.org/10.59324/ejaset.2026.4(6).13
Primary Topic
Geophysical and Geoelectrical Methods
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Validation of Aquifer Zones Derived from ADMT Interpretation Based on Well Drilling in Jimbaran, Bali

Ni Nyoman Pujianiki, I Nengah Simpen
HAL
Geophysical and Geoelectrical Methods
article

Validation of Aquifer Zones Derived from ADMT Interpretation Based on Well Drilling in Jimbaran, Bali

Ni Nyoman Pujianiki, I Nengah Simpen
article en

Abstract

This study was motivated by the importance of groundwater exploration in carbonate rocks in the USDI area of Udayana University, Jimbaran, Bali. Its primary focus is to evaluate the degree of agreement between the results of Audio Magnetotelluric (ADMT) geophysical interpretation and actual subsurface conditions obtained from well drilling. ADMT measurements were conducted at track positions X = 0, 2, 4, 6, 8, and 10 m at depths ranging from 10 to 200 m, with 10-meter intervals. On the X = 4 m profile, resistivity values of 12.11–12.57 Ωm were recorded at depths of 20–60 m, which then decreased significantly to 7.62 Ωm at a depth of 70 m and 7.77 Ωm at a depth of 80 m. The accuracy of the ADMT interpretation was validated in the field when water was first encountered at a depth of 70 m. Drilling continued to a depth of 80 m, confirming that the 70–80 m interval is a verified aquifer zone. Subsequently, a submersible pump was installed at a depth of 75 m. Although the aquifer zone has been validated, the pump’s position at a depth of 75 m leaves a 5-meter gap to the bottom of the well and is very close to the water inflow zone. This makes operational performance vulnerable to dynamic water levels, drawdown, submergence, well development, and potential sediment content. Additionally, conductive anomalies at depths greater than 80 m cannot yet be confirmed as an aquifer because they have not been drilled. To ensure the well’s hydraulic efficiency and feasibility, the study recommends conducting a step-drawdown test, a constant-rate pumping test, and a recovery test, accompanied by periodic monitoring of EC/TDS values and turbidity to determine a safe water withdrawal rate.

HALVol. 4(6)
Geophysical and Geoelectrical Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon