MET-Based Intensity Classification Across Predefined Workload Conditions and Environmental Temperatures While Wearing Chemical Protective Clothing

Chemical protective clothing may increase metabolic demands during occupational tasks. This study examined metabolic demands and metabolic equivalent of task (MET)-based intensity classifications across predefined workload conditions and environmental temperatures while participants wore NPS-108 chemical protective clothing. Fifteen male participants completed 27 trials comprising three temperatures (15, 25, and 35 °C; 70% relative humidity) and nine workload conditions combining external loads (0, 10, and 20 kg) with locomotion speeds (4, 6, and 8 km/h). Metabolic responses during 15 min of treadmill locomotion were measured using a COSMED K5 portable metabolic system and analyzed using a two-way repeated-measures analysis of variance with pairwise comparisons. Intensity was classified based on group mean MET values. All conditions at 4 km/h were moderate intensity (3.8–5.3 METs), and all conditions at 8 km/h were vigorous intensity (9.0–12.8 METs). At 6 km/h, the no-load condition was moderate at 15 °C but vigorous at 25 °C and 35 °C, whereas both loaded conditions were vigorous at all temperatures. The repeated-measures ANOVA identified main effects of temperature and workload condition and a temperature-by-workload-condition interaction. After Bonferroni adjustment, MET values at 15 °C were lower than those at 35 °C in all nine workload conditions and lower than those at 25 °C in six conditions; 25 °C and 35 °C differed in one condition. These findings provide a practical reference for comparing the metabolic intensity of the tested workload conditions and may assist in planning training and occupational tasks performed in chemical protective clothing.

Authors

Institutions

Publication Details

Journal
Life
Published
2026-11-18
DOI
https://doi.org/10.3390/life16111954
Primary Topic
Occupational Health and Performance
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

MET-Based Intensity Classification Across Predefined Workload Conditions and Environmental Temperatures While Wearing Chemical Protective Clothing

Jing-Hsuan Chen, Szu‐Kai Fu, Fu-Shun Hsu, Yuh-Chuan Shih et al.
Life
Occupational Health and Performance
article

MET-Based Intensity Classification Across Predefined Workload Conditions and Environmental Temperatures While Wearing Chemical Protective Clothing

Jing-Hsuan Chen, Szu‐Kai Fu, Fu-Shun Hsu, Yuh-Chuan Shih, Chia-Yu Tang, Chih-Yu Hsiao, Yun-Chung Tseng, Jing-Jie Lin
article en

Abstract

Chemical protective clothing may increase metabolic demands during occupational tasks. This study examined metabolic demands and metabolic equivalent of task (MET)-based intensity classifications across predefined workload conditions and environmental temperatures while participants wore NPS-108 chemical protective clothing. Fifteen male participants completed 27 trials comprising three temperatures (15, 25, and 35 °C; 70% relative humidity) and nine workload conditions combining external loads (0, 10, and 20 kg) with locomotion speeds (4, 6, and 8 km/h). Metabolic responses during 15 min of treadmill locomotion were measured using a COSMED K5 portable metabolic system and analyzed using a two-way repeated-measures analysis of variance with pairwise comparisons. Intensity was classified based on group mean MET values. All conditions at 4 km/h were moderate intensity (3.8–5.3 METs), and all conditions at 8 km/h were vigorous intensity (9.0–12.8 METs). At 6 km/h, the no-load condition was moderate at 15 °C but vigorous at 25 °C and 35 °C, whereas both loaded conditions were vigorous at all temperatures. The repeated-measures ANOVA identified main effects of temperature and workload condition and a temperature-by-workload-condition interaction. After Bonferroni adjustment, MET values at 15 °C were lower than those at 35 °C in all nine workload conditions and lower than those at 25 °C in six conditions; 25 °C and 35 °C differed in one condition. These findings provide a practical reference for comparing the metabolic intensity of the tested workload conditions and may assist in planning training and occupational tasks performed in chemical protective clothing.

LifeVol. 16(11)
National Taiwan University (TW), University of Taipei (TW), Taipei Municipal YangMing Hospital (TW), National Defense University (TW), Taipei City Hospital (TW), National Chengchi University (TW)
Ministry of National Defense
Good health and well-being
Occupational Health and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon