Modelling and Simulation of Fouling in a Shell-and-Tube Heat Exchanger for Performance Improvement: An ANSYS-Based Case Study

ABSTRACT: Fouling on heat transfer surfaces lowers the thermal efficiency of shell-andtube heat exchangers, increases energy consumption and causes unplanned shutdowns in oil and gas processing. This study modelled and simulated fouling in a horizontal BEMtype shell-and-tube exchanger (TEMA standard, 64 stainless-steel tubes) that cools a hydrocarbon stream with water at an oil and gas facility in Bonny Island, Nigeria. The exchanger was modelled and its steady-state operation simulated in ANSYS 14.0 using the facility’s design and operating data. Fouling behaviour was assessed over twelve simulated monthly cases, with fouling resistance (Rf) calculated from the clean and fouled overall heat transfer coefficients. In the first month, fouling reduced heat duty by 36.25% relative to the clean exchanger and the overall heat transfer coefficient (U) fell from 26.26–27.02 to 16.15 W/m²·°C. Over the twelve cases, Rf rose from 0.0238 to 0.0264 m²·°C/W while U fell to 15.24 W/m²·°C. Regression showed that Rf was strongly related to U (power law, R² = 0.986), time (power law, R² = 0.951) and mass flow rate (logarithmic, R² = 0.902), and more weakly to log mean temperature difference (linear, R² = 0.777). Because mass flow rate and time were varied together, their effects could not be separated. The relationships offer a simple basis for forecasting fouling growth and planning cleaning, but they are model-based and require validation against measured plant data. Keywords: Fouling; Shell-and-tube heat exchanger; ANSYS; Heat Transfer Performance; Fouling Resistance; Regression Modelling

Authors

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-18
DOI
https://doi.org/10.5281/zenodo.24330545
Primary Topic
Heat Transfer and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Modelling and Simulation of Fouling in a Shell-and-Tube Heat Exchanger for Performance Improvement: An ANSYS-Based Case Study

C. V. Ossia, Francis Chimobi Akpa
1 links
Zenodo (CERN European Organization for Nuclear Research)
Heat Transfer and Optimization
article

Modelling and Simulation of Fouling in a Shell-and-Tube Heat Exchanger for Performance Improvement: An ANSYS-Based Case Study

C. V. Ossia, Francis Chimobi Akpa
article en

Abstract

ABSTRACT: Fouling on heat transfer surfaces lowers the thermal efficiency of shell-andtube heat exchangers, increases energy consumption and causes unplanned shutdowns in oil and gas processing. This study modelled and simulated fouling in a horizontal BEMtype shell-and-tube exchanger (TEMA standard, 64 stainless-steel tubes) that cools a hydrocarbon stream with water at an oil and gas facility in Bonny Island, Nigeria. The exchanger was modelled and its steady-state operation simulated in ANSYS 14.0 using the facility’s design and operating data. Fouling behaviour was assessed over twelve simulated monthly cases, with fouling resistance (Rf) calculated from the clean and fouled overall heat transfer coefficients. In the first month, fouling reduced heat duty by 36.25% relative to the clean exchanger and the overall heat transfer coefficient (U) fell from 26.26–27.02 to 16.15 W/m²·°C. Over the twelve cases, Rf rose from 0.0238 to 0.0264 m²·°C/W while U fell to 15.24 W/m²·°C. Regression showed that Rf was strongly related to U (power law, R² = 0.986), time (power law, R² = 0.951) and mass flow rate (logarithmic, R² = 0.902), and more weakly to log mean temperature difference (linear, R² = 0.777). Because mass flow rate and time were varied together, their effects could not be separated. The relationships offer a simple basis for forecasting fouling growth and planning cleaning, but they are model-based and require validation against measured plant data. Keywords: Fouling; Shell-and-tube heat exchanger; ANSYS; Heat Transfer Performance; Fouling Resistance; Regression Modelling

Zenodo (CERN European Organization for Nuclear Research)
University of Port Harcourt (NG)
Heat Transfer and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon