Evaluating the Convective Coefficient for Cylindrical Radiation Thermometers in the Conditions of Interest for Outdoor Thermal Comfort: A CFD Analysis

Slender cylindrical radiation thermometers have been proposed as an alternative to conventional globe thermometers for outdoor thermal comfort assessment, as they better represent pedestrians’ exposure to solar radiation. Nevertheless, determining the mean radiant temperature from their measurements requires an accurate estimate of the convective heat transfer coefficient. For these devices, forced and natural convection are governed by different characteristic lengths, namely the cylinder diameter, D, and height, H, respectively. Based on measurements from a preliminary outdoor experimental campaign with a cylindrical radiation thermometer, the Richardson number calculated using these two characteristic lengths, RiHD, was found to be of the order of unity, initially suggesting the possible occurrence of mixed convection. However, suitable mixed convection correlations for this configuration are unavailable. Therefore, Computational Fluid Dynamics simulations were conducted to determine the convective heat transfer coefficient under different conditions. The results showed that, in 23 out of 25 investigated cases, the convective coefficients obtained from the numerical simulations fell within the range of established forced convection correlations or exceeded its upper limit by less than 1%. Larger deviations, of 5.2% and 9.2%, occurred only under combinations of very low wind speeds and large air-cylinder temperature differences, unlikely to occur in typical outdoor thermal comfort applications. Furthermore, the conventional Richardson number thresholds were found to be unsuitable for interpreting RiHD, whereas the Richardson number calculated using the cylinder diameter for both natural and forced convection, RiD, provided indications consistent with the identified convection regimes. Overall, these findings support the use of standard forced convection correlations for estimating the convective coefficient of cylindrical radiation thermometers under typical outdoor conditions, simplifying the determination of the mean radiant temperature and supporting the assessment of passive heat mitigation strategies in urban environments.

Authors

Institutions

Publication Details

Journal
Fluids
Published
2026-11-18
DOI
https://doi.org/10.3390/fluids11110292
Primary Topic
Wind and Air Flow Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Evaluating the Convective Coefficient for Cylindrical Radiation Thermometers in the Conditions of Interest for Outdoor Thermal Comfort: A CFD Analysis

Roberta Caruana, Adriana Angelotti, Luca Davide Marocco, Manfredo Guilizzoni
1 links
Fluids
Wind and Air Flow Studies
article

Evaluating the Convective Coefficient for Cylindrical Radiation Thermometers in the Conditions of Interest for Outdoor Thermal Comfort: A CFD Analysis

Roberta Caruana, Adriana Angelotti, Luca Davide Marocco, Manfredo Guilizzoni
article en

Abstract

Slender cylindrical radiation thermometers have been proposed as an alternative to conventional globe thermometers for outdoor thermal comfort assessment, as they better represent pedestrians’ exposure to solar radiation. Nevertheless, determining the mean radiant temperature from their measurements requires an accurate estimate of the convective heat transfer coefficient. For these devices, forced and natural convection are governed by different characteristic lengths, namely the cylinder diameter, D, and height, H, respectively. Based on measurements from a preliminary outdoor experimental campaign with a cylindrical radiation thermometer, the Richardson number calculated using these two characteristic lengths, RiHD, was found to be of the order of unity, initially suggesting the possible occurrence of mixed convection. However, suitable mixed convection correlations for this configuration are unavailable. Therefore, Computational Fluid Dynamics simulations were conducted to determine the convective heat transfer coefficient under different conditions. The results showed that, in 23 out of 25 investigated cases, the convective coefficients obtained from the numerical simulations fell within the range of established forced convection correlations or exceeded its upper limit by less than 1%. Larger deviations, of 5.2% and 9.2%, occurred only under combinations of very low wind speeds and large air-cylinder temperature differences, unlikely to occur in typical outdoor thermal comfort applications. Furthermore, the conventional Richardson number thresholds were found to be unsuitable for interpreting RiHD, whereas the Richardson number calculated using the cylinder diameter for both natural and forced convection, RiD, provided indications consistent with the identified convection regimes. Overall, these findings support the use of standard forced convection correlations for estimating the convective coefficient of cylindrical radiation thermometers under typical outdoor conditions, simplifying the determination of the mean radiant temperature and supporting the assessment of passive heat mitigation strategies in urban environments.

FluidsVol. 11(11)
Politecnico di Milano (IT)
Wind and Air Flow Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon