Concentration-Aware Model Predictive Control for Pressure–Flow Coordination in Slurry Shield Circulation Systems
Coordinated pressure and discharge-flow regulation is a practical challenge in slurry shield circulation systems because changes in solids concentration modify pipeline resistance and the flow required by a prescribed transport criterion. This paper investigates concentration-aware model predictive control (CA-MPC) for a reduced two-pump hydraulic circulation unit. A four-state nonlinear model describes chamber pressure, inlet and discharge flows, and well-mixed solids concentration. A locally updated prediction model and a concentration-dependent minimum discharge-flow constraint are implemented within an incremental quadratic-programming controller, subject to pump-command, rate, and chamber-pressure limits. Numerical comparisons with feedforward-assisted proportional–integral control and nominal-model MPC consider set-point changes, inlet-concentration variation, excavation disturbances, and a low-flow conflict scenario. A two-factor comparison distinguishes predictor-information updating from transport-constraint scheduling. In the latter scenario, scheduling the modeled minimum-flow constraint reduced sampled threshold-violation duration from 131.5 s to zero, at the expense of increasing flow-tracking root-mean-square error from approximately 14.0 to 48.5 L/s. Predictor-information updating alone did not improve one-step prediction accuracy in the evaluated case, and larger hydraulic mismatch degraded the constraint benefit. In the matched safety case, the proposed dynamic bound and a predeclared fixed-conservative bound both achieved zero sampled model-threshold violations; the dynamic bound reduced flow RMSE from 54.784 to 48.506 L/s. The joint sensitivity study also revealed model-defined violations for the dynamic controller under increased resistance mismatch and threshold slope. These results quantify an engineering trade-off between pressure–flow tracking and model-defined transport limits. Because the hydraulic parameters and transport threshold are not experimentally calibrated, the findings apply to the stated numerical model and do not demonstrate field-scale deposition prevention.
Authors
- Guangming Zhang (ORCID: https://orcid.org/0000-0002-9566-7865)
- Zhihua Liu
- Xiaoxiong Zhou (ORCID: https://orcid.org/0009-0008-0796-0916)
- Ruiqiang Fan
- Shanshan Huang
Institutions
- Nanjing Tech University (CN)
Publication Details
- Journal
- Applied Sciences
- Published
- 2026-11-18
- DOI
- https://doi.org/10.3390/app162211450
- Primary Topic
- Advanced Control Systems Optimization
- Type
- article
- Field-Weighted Citation Impact
- 0.00