Assessment of the Level of Implementation of Quality Assurance and Quality Control Programs in Medical Imaging and Image-Guided Radiation Therapy Departments

Quality assurance and quality control (QA/QC) programs are part of routine quality management in medical imaging and image-guided radiation therapy (IGRT). This study described healthcare professionals’ perceived level of QA/QC implementation in selected Philippine healthcare institutions. A descriptive-quantitative survey was conducted among 50 professionals involved in QA/QC-related activities. A researcher-developed, 48-item questionnaire assessed eight domains: equipment quality assurance, radiation protection, image quality assurance, preventive maintenance, documentation, personnel competency, standard operating procedures, and regulatory compliance. Responses were summarized using frequencies, percentages, weighted means, standard deviations, and rankings. Among the seven domains for which results were available in the manuscript, regulatory compliance received the highest composite mean (WM = 4.58), followed by radiation protection (WM = 4.39), personnel competency (WM = 4.35), image quality assurance (WM = 4.34), documentation (WM = 4.32), and equipment quality assurance (WM = 4.30). Preventive maintenance received the lowest mean (WM = 4.20), interpreted as Implemented rather than Highly Implemented. Radiologic technologists comprised 40.0% of respondents; 54.0% held a bachelor’s degree, and respondents were equally distributed between government and private institutions. These results represent respondents’ assessments and do not independently verify institutional compliance or establish effects on patient outcomes. Before publication, the years-of-experience distribution, standard operating procedures results, institutional sampling details, and ethics-review status must be verified and completed.

Authors

Institutions

Publication Details

Journal
International Journal of Education, Research, and Innovation Perspectives
Published
2026-11-18
DOI
https://doi.org/10.5281/zenodo.24346402
Primary Topic
Quality and Safety in Healthcare
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Assessment of the Level of Implementation of Quality Assurance and Quality Control Programs in Medical Imaging and Image-Guided Radiation Therapy Departments

Marifel O. Sison, Lou Diamond Culanag, Jericho Espiritu, Keanna Cheska Tipo et al.
1 links
International Journal of Education, Research, and Innovation Perspectives
Quality and Safety in Healthcare
article

Assessment of the Level of Implementation of Quality Assurance and Quality Control Programs in Medical Imaging and Image-Guided Radiation Therapy Departments

Marifel O. Sison, Lou Diamond Culanag, Jericho Espiritu, Keanna Cheska Tipo, Jonvier Valentin, Jess Michael Eslao, Jessa Mae Pinili, Reynalyn Corpuz
article en

Abstract

Quality assurance and quality control (QA/QC) programs are part of routine quality management in medical imaging and image-guided radiation therapy (IGRT). This study described healthcare professionals’ perceived level of QA/QC implementation in selected Philippine healthcare institutions. A descriptive-quantitative survey was conducted among 50 professionals involved in QA/QC-related activities. A researcher-developed, 48-item questionnaire assessed eight domains: equipment quality assurance, radiation protection, image quality assurance, preventive maintenance, documentation, personnel competency, standard operating procedures, and regulatory compliance. Responses were summarized using frequencies, percentages, weighted means, standard deviations, and rankings. Among the seven domains for which results were available in the manuscript, regulatory compliance received the highest composite mean (WM = 4.58), followed by radiation protection (WM = 4.39), personnel competency (WM = 4.35), image quality assurance (WM = 4.34), documentation (WM = 4.32), and equipment quality assurance (WM = 4.30). Preventive maintenance received the lowest mean (WM = 4.20), interpreted as Implemented rather than Highly Implemented. Radiologic technologists comprised 40.0% of respondents; 54.0% held a bachelor’s degree, and respondents were equally distributed between government and private institutions. These results represent respondents’ assessments and do not independently verify institutional compliance or establish effects on patient outcomes. Before publication, the years-of-experience distribution, standard operating procedures results, institutional sampling details, and ethics-review status must be verified and completed.

International Journal of Education, Research, and Innovation Perspectives
University of Perpetual Help System DALTA (PH), University of Perpetual Help System Laguna (PH)
Good health and well-being
Quality and Safety in Healthcare
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon