Augmented reality–based smart glasses to support procedural performance in ultrasound-guided central venous catheterization: a simulation study

Background: Augmented reality (AR)–based smart glasses combined with real-time telementoring have the potential to support image-guided procedures by improving visualization and enabling remote expert guidance. This approach may be particularly valuable in settings with limited access to experienced specialists. However, its integration into clinical workflows remains a challenge. Methods: In this simulation-based study, twelve physicians experienced in ultrasound-guided central venous catheter (US-CVC) insertion performed procedures using an AR-based setup integrating smart glasses with real-time ultrasound image transmission and remote communication. Usability and perceived impact on procedural performance were assessed using a Technology Acceptance Model (TAM)–based questionnaire (10-point Likert scale). Internal consistency and relationships between TAM domains were analyzed using Cronbach’s alpha and Spearman’s correlation. Results: The system demonstrated acceptable internal consistency (α = 0.726). Participants reported favorable perceptions regarding visualization, workflow integration, and procedural confidence. Most participants indicated improved visualization of anatomical structures, reduced need to shift attention between the operative field and external monitors, and increased confidence during task execution. Higher scores were observed in perceived usefulness, attitude toward use, and behavioral intention domains. Conclusion: The proposed AR-based smart glasses system was feasible and well accepted in a simulated environment. Participants reported positive perceptions regarding visualization, workflow integration, and remote expert guidance, suggesting that this approach may support procedural training and expand access to specialized expertise. Future controlled studies incorporating objective performance metrics and clinical outcomes are needed to confirm its effectiveness.

Authors

Institutions

Publication Details

Journal
Journal of Community Hospital Internal Medicine Perspectives
Published
2026-11-17
DOI
https://doi.org/10.55729/2000-9666.1656
Primary Topic
Augmented Reality Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Augmented reality–based smart glasses to support procedural performance in ultrasound-guided central venous catheterization: a simulation study

Luiz Gustavo de Paulo, Luciano de Andrade, Carlos Edmundo Rodrigues Fontes, Vlaudimir Dias Marques et al.
Journal of Community Hospital Internal Medicine Perspectives
Augmented Reality Applications
article

Augmented reality–based smart glasses to support procedural performance in ultrasound-guided central venous catheterization: a simulation study

Luiz Gustavo de Paulo, Luciano de Andrade, Carlos Edmundo Rodrigues Fontes, Vlaudimir Dias Marques, Sanderland José Tavares Gurgel, Júlia Loverde Gabella, Miyoko Massago, Guilherme Augusto Guimarães Resende, Edvaldo Vieira de Campos, Mateus de Amorim Aboboreira, Luana Vieira Duran, Felipe Hideaki Ueda
article en

Abstract

Background: Augmented reality (AR)–based smart glasses combined with real-time telementoring have the potential to support image-guided procedures by improving visualization and enabling remote expert guidance. This approach may be particularly valuable in settings with limited access to experienced specialists. However, its integration into clinical workflows remains a challenge. Methods: In this simulation-based study, twelve physicians experienced in ultrasound-guided central venous catheter (US-CVC) insertion performed procedures using an AR-based setup integrating smart glasses with real-time ultrasound image transmission and remote communication. Usability and perceived impact on procedural performance were assessed using a Technology Acceptance Model (TAM)–based questionnaire (10-point Likert scale). Internal consistency and relationships between TAM domains were analyzed using Cronbach’s alpha and Spearman’s correlation. Results: The system demonstrated acceptable internal consistency (α = 0.726). Participants reported favorable perceptions regarding visualization, workflow integration, and procedural confidence. Most participants indicated improved visualization of anatomical structures, reduced need to shift attention between the operative field and external monitors, and increased confidence during task execution. Higher scores were observed in perceived usefulness, attitude toward use, and behavioral intention domains. Conclusion: The proposed AR-based smart glasses system was feasible and well accepted in a simulated environment. Participants reported positive perceptions regarding visualization, workflow integration, and remote expert guidance, suggesting that this approach may support procedural training and expand access to specialized expertise. Future controlled studies incorporating objective performance metrics and clinical outcomes are needed to confirm its effectiveness.

Journal of Community Hospital Internal Medicine PerspectivesVol. 16(6)
Universidade Estadual de Maringá (BR), Centro Universitário Cesumar (BR)
Augmented Reality Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon