Adaptive Neuro-Fuzzy Inference System (ANFIS)-Based Controller for Unified Power Quality Conditioning (UPQC) in Islanded Microgrid

This study investigates the development and performance of an ANFIS-controlled Unified Power Quality Conditioner (UPQC) integrated into a solar photovoltaic-battery islanded microgrid for voltage regulation, harmonic mitigation, transient stability, and active-power balancing in the Tende-Ama Ogu/Bolo distribution system, Rivers State, Nigeria. The study first assessed the solar energy resource at Tende-Ama Community using Global Horizontal Irradiance (GHI) data obtained from the NASA POWER database for January 2024 to August 2026. An average daily GHI of 4.13 kWh/m²/day was obtained, with PV capacity factors of 62.79%, 60.24%, and 60.19% for the assessed 2024, 2025, and 2026 periods, respectively. A MATLAB/Simulink model of the solar-battery islanded microgrid was subsequently developed, comprising a PV array, MPPT-controlled boost converter, DC-AC inverter, BESS with bidirectional boost-buck converter, balanced load, and nonlinear rectifier load. Load-flow analysis of the Tende-Ama Ogu/Bolo distribution system established the baseline voltage profile under heavy loading and identified Bus 5, Bus 10, Bus 13, Bus 14, and Bus 18 as voltage-weak buses, with voltage magnitudes of 93.25%, 92.77%, 93.50%, 91.59%, and 90.72%, respectively. A UPQC was then integrated at the point of interconnection to provide series and shunt compensation. Harmonic assessment showed that the total harmonic distortion of 20.62% was reduced to 1.15% following UPQC compensation. Under transient voltage disturbances, the UPQC dynamically compensated for voltage sag and swell while maintaining a stable load voltage. Under heavy loading, integration of the ANFIS-controlled UPQC improved all bus voltages to within the 0.95–1.05 pu acceptable operating range, with the previously weak buses improved to 99.327%, 99.091%, 99.945%, 99.500%, and 99.536%, respectively. The findings demonstrate that the integrated ANFIS-controlled UPQC and coordinated PV-BESS control strategy provides an effective approach for improving voltage regulation, mitigating harmonic disturbances, supporting transient stability, and maintaining active-power balance in a solar-battery islanded microgrid.

Authors

Institutions

Publication Details

Journal
Iconic Research and Engineering Journals
Published
2026-11-18
DOI
https://doi.org/10.64388/ire1725278
Primary Topic
Power Quality and Harmonics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Adaptive Neuro-Fuzzy Inference System (ANFIS)-Based Controller for Unified Power Quality Conditioning (UPQC) in Islanded Microgrid

Anthony Kevwe, YARHERE, E.D. Ekeriance, E.C. Obuah
Iconic Research and Engineering Journals
Power Quality and Harmonics
article

Adaptive Neuro-Fuzzy Inference System (ANFIS)-Based Controller for Unified Power Quality Conditioning (UPQC) in Islanded Microgrid

Anthony Kevwe, YARHERE, E.D. Ekeriance, E.C. Obuah
article en

Abstract

This study investigates the development and performance of an ANFIS-controlled Unified Power Quality Conditioner (UPQC) integrated into a solar photovoltaic-battery islanded microgrid for voltage regulation, harmonic mitigation, transient stability, and active-power balancing in the Tende-Ama Ogu/Bolo distribution system, Rivers State, Nigeria. The study first assessed the solar energy resource at Tende-Ama Community using Global Horizontal Irradiance (GHI) data obtained from the NASA POWER database for January 2024 to August 2026. An average daily GHI of 4.13 kWh/m²/day was obtained, with PV capacity factors of 62.79%, 60.24%, and 60.19% for the assessed 2024, 2025, and 2026 periods, respectively. A MATLAB/Simulink model of the solar-battery islanded microgrid was subsequently developed, comprising a PV array, MPPT-controlled boost converter, DC-AC inverter, BESS with bidirectional boost-buck converter, balanced load, and nonlinear rectifier load. Load-flow analysis of the Tende-Ama Ogu/Bolo distribution system established the baseline voltage profile under heavy loading and identified Bus 5, Bus 10, Bus 13, Bus 14, and Bus 18 as voltage-weak buses, with voltage magnitudes of 93.25%, 92.77%, 93.50%, 91.59%, and 90.72%, respectively. A UPQC was then integrated at the point of interconnection to provide series and shunt compensation. Harmonic assessment showed that the total harmonic distortion of 20.62% was reduced to 1.15% following UPQC compensation. Under transient voltage disturbances, the UPQC dynamically compensated for voltage sag and swell while maintaining a stable load voltage. Under heavy loading, integration of the ANFIS-controlled UPQC improved all bus voltages to within the 0.95–1.05 pu acceptable operating range, with the previously weak buses improved to 99.327%, 99.091%, 99.945%, 99.500%, and 99.536%, respectively. The findings demonstrate that the integrated ANFIS-controlled UPQC and coordinated PV-BESS control strategy provides an effective approach for improving voltage regulation, mitigating harmonic disturbances, supporting transient stability, and maintaining active-power balance in a solar-battery islanded microgrid.

Iconic Research and Engineering JournalsVol. 10(5)
Rivers State University (NG)
Industry, innovation and infrastructure, Affordable and clean energy
Power Quality and Harmonics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon