On the optimal time points for assessing the cortisol response in the high-dose ACTH stimulation test – a literature review

The high-dose ACTH stimulation test is used to assess adrenal insufficiency. Although the test has a rather simple design, many variables in pretest conditions, performing the test and cortisol methods impact the interpretation of the test result, for which rigid cut-offs were previously used. There is growing attention to standardized work-up and using well-standardized analytical methods and assay-specific cortisol cut-offs. There is less consensus on whether post-stimulation serum cortisol concentrations should be measured at 30 minutes (t30) or 60 minutes (t60) or both. Often the same cortisol cut-off is used for measurements at both time points, even though the continuous cortisol response in this time frame suggests using different cut-offs. We reviewed studies describing cortisol measurements at t30 and t60 during the high-dose AST and studied diagnostic accuracy. We noted that cortisol cut-offs should be specific to the assay used and, when using modern assays, lower than the original 500 or 550 nmol/L. When using a single cut-off for t30 and t60, measurements at the t60 time point showed higher specificity. However, when using time point-specific cortisol cut-offs, the specificity of cortisol measurements at t30 or t60 appeared comparable. In conclusion, serum cortisol measurements at t30 and t60 during the high-dose ACTH stimulation test seem equally accurate. A similar performance may be achieved using either time point alone, provided time point and assay-specific cut-offs are used. It should be noted, however, that the results of the high-dose ACTH stimulation test should always be interpreted within the clinical context.

Authors

Institutions

Publication Details

Journal
Journal of Molecular Endocrinology
Published
2026-11-18
DOI
https://doi.org/10.1530/jme-26-0058
Primary Topic
Adrenal Hormones and Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

On the optimal time points for assessing the cortisol response in the high-dose ACTH stimulation test – a literature review

Annenienke C. van de Ven, Nienke Ruurdje Biermasz, Jacquelien J Hillebrand, Annemieke C. Heijboer et al.
1 links
Journal of Molecular Endocrinology
Adrenal Hormones and Disorders
article

On the optimal time points for assessing the cortisol response in the high-dose ACTH stimulation test – a literature review

Annenienke C. van de Ven, Nienke Ruurdje Biermasz, Jacquelien J Hillebrand, Annemieke C. Heijboer, Karlijn Koops, Michiel N. Kerstens, Judith MA Emmen
article en

Abstract

The high-dose ACTH stimulation test is used to assess adrenal insufficiency. Although the test has a rather simple design, many variables in pretest conditions, performing the test and cortisol methods impact the interpretation of the test result, for which rigid cut-offs were previously used. There is growing attention to standardized work-up and using well-standardized analytical methods and assay-specific cortisol cut-offs. There is less consensus on whether post-stimulation serum cortisol concentrations should be measured at 30 minutes (t30) or 60 minutes (t60) or both. Often the same cortisol cut-off is used for measurements at both time points, even though the continuous cortisol response in this time frame suggests using different cut-offs. We reviewed studies describing cortisol measurements at t30 and t60 during the high-dose AST and studied diagnostic accuracy. We noted that cortisol cut-offs should be specific to the assay used and, when using modern assays, lower than the original 500 or 550 nmol/L. When using a single cut-off for t30 and t60, measurements at the t60 time point showed higher specificity. However, when using time point-specific cortisol cut-offs, the specificity of cortisol measurements at t30 or t60 appeared comparable. In conclusion, serum cortisol measurements at t30 and t60 during the high-dose ACTH stimulation test seem equally accurate. A similar performance may be achieved using either time point alone, provided time point and assay-specific cut-offs are used. It should be noted, however, that the results of the high-dose ACTH stimulation test should always be interpreted within the clinical context.

Journal of Molecular Endocrinology
University Medical Center Groningen (NL), Radboud University Nijmegen (NL), University of Groningen (NL), Leiden University Medical Center (NL), Amsterdam UMC Location University of Amsterdam (NL), Radboud University Medical Center (NL), Amphia Ziekenhuis (NL), Amsterdam University Medical Centers (NL), Amsterdam Gastroenterology Endocrinology Metabolism (NL), Amsterdam Reproduction Development (NL), Vrije Universiteit Amsterdam (NL), University of Amsterdam (NL), Amsterdam UMC Location Vrije Universiteit Amsterdam (NL)
Good health and well-being
Adrenal Hormones and Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon