Predicting Physiological-Level Glucose In Vitro with Terahertz ATR Spectroscopy: A Study of Robust Calibration

Noninvasive glucose sensing has been the focus of extensive optical research, yet terahertz (THz) spectroscopy remains comparatively underexplored for reliable glucose quantification at physiological concentrations. This is partly because aqueous THz measurements are strongly affected by experimental variability, which can obscure the weak glucose-induced spectral response. In this study, we investigate whether standard THz time-domain spectroscopy (TDS) in an attenuated total reflection (ATR) geometry can provide reliable, physically interpretable, and generalizable in vitro glucose quantification in liquid samples at physiological concentrations. Glucose solutions at physiological concentrations were measured in phosphate-buffered saline, deionized water, and artificial interstitial fluid to evaluate the reproducibility of the glucose-induced spectral response across optically distinct sample matrices. By combining simultaneous amplitude and phase detection with a randomized experimental protocol, differential THz-ATR spectra were used to isolate glucose-induced spectral contrast from systematic experimental effects. The differential spectra showed a reproducible glucose-dependent response across matrices, with amplitude and phase trends that followed the expected optical response of aqueous glucose solutions. Partial least-squares regression was used to assess quantitative glucose prediction and calibration generalizability. The results demonstrate that glucose-induced spectral contrast can be reproducibly retrieved across liquid matrices and used for prediction at physiological concentrations. Both pooled-matrix regression and cross-matrix calibration transfer further indicate that the calibration models can generalize across matrix conditions, with replicate repeatability remaining a key factor governing performance. To the best of our knowledge, this is the first demonstration of robust and physically interpretable in vitro glucose quantification in liquids at physiological concentrations using standard THz-TDS. These results provide a critical first step toward clarifying the role of THz spectroscopy in glucose sensing, from liquid-phase model systems to future transdermal applications.

Authors

Institutions

Publication Details

Journal
ACS Omega
Published
2026-11-18
DOI
https://doi.org/10.1021/acsomega.6c09852
Primary Topic
Terahertz technology and applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Predicting Physiological-Level Glucose In Vitro with Terahertz ATR Spectroscopy: A Study of Robust Calibration

Simon Jappe Lange, Peter Uhd Jepsen, Lorenza Pia Foglia
ACS Omega
Terahertz technology and applications
article

Predicting Physiological-Level Glucose In Vitro with Terahertz ATR Spectroscopy: A Study of Robust Calibration

Simon Jappe Lange, Peter Uhd Jepsen, Lorenza Pia Foglia
article en

Abstract

Noninvasive glucose sensing has been the focus of extensive optical research, yet terahertz (THz) spectroscopy remains comparatively underexplored for reliable glucose quantification at physiological concentrations. This is partly because aqueous THz measurements are strongly affected by experimental variability, which can obscure the weak glucose-induced spectral response. In this study, we investigate whether standard THz time-domain spectroscopy (TDS) in an attenuated total reflection (ATR) geometry can provide reliable, physically interpretable, and generalizable in vitro glucose quantification in liquid samples at physiological concentrations. Glucose solutions at physiological concentrations were measured in phosphate-buffered saline, deionized water, and artificial interstitial fluid to evaluate the reproducibility of the glucose-induced spectral response across optically distinct sample matrices. By combining simultaneous amplitude and phase detection with a randomized experimental protocol, differential THz-ATR spectra were used to isolate glucose-induced spectral contrast from systematic experimental effects. The differential spectra showed a reproducible glucose-dependent response across matrices, with amplitude and phase trends that followed the expected optical response of aqueous glucose solutions. Partial least-squares regression was used to assess quantitative glucose prediction and calibration generalizability. The results demonstrate that glucose-induced spectral contrast can be reproducibly retrieved across liquid matrices and used for prediction at physiological concentrations. Both pooled-matrix regression and cross-matrix calibration transfer further indicate that the calibration models can generalize across matrix conditions, with replicate repeatability remaining a key factor governing performance. To the best of our knowledge, this is the first demonstration of robust and physically interpretable in vitro glucose quantification in liquids at physiological concentrations using standard THz-TDS. These results provide a critical first step toward clarifying the role of THz spectroscopy in glucose sensing, from liquid-phase model systems to future transdermal applications.

ACS Omega
Technical University of Denmark (DK)
Novo Nordisk, Danmarks Tekniske Universitet, Novo Nordisk Fonden
Good health and well-being
Terahertz technology and applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon