Development and temporal validation of a gradient boosting machine model for endometriosis using routine laboratory indicators

Background Endometriosis (EM) is a chronic gynecological disorder for which timely diagnosis remains challenging. Routine laboratory indicators may inform EM identification, but their performance in multivariable diagnostic models requires rigorous validation. This study aimed to develop and temporally validate a machine learning model for identifying EM among women undergoing gynecological evaluation. Methods This retrospective, single-center study included 2,452 women (839 with EM and 1,613 disease controls). Participants were allocated to training ( n = 1,029), internal test ( n = 441), and temporal validation ( n = 982) cohorts. Twelve candidate predictors were evaluated using least absolute shrinkage and selection operator regression and Boruta. Six algorithms were compared using repeated nested cross-validation. The selected model underwent discrimination, calibration, exploratory decision curve, clinical comparator, and sensitivity analyses. Results Eight indicators were selected: triglycerides, high-density lipoprotein cholesterol, low-density lipoprotein cholesterol, lymphocyte count, neutrophil count, monocyte count, platelet count, and CA125. Gradient boosting machine (GBM) achieved the highest mean area under the receiver operating characteristic curve (AUC) during repeated nested cross-validation (0.8483). The GBM achieved AUCs of 0.8401 (95% CI, 0.8006–0.8797) internally and 0.8565 (95% CI, 0.8320–0.8810) temporally. At a fixed threshold of 0.50, sensitivity was 55.63% and 59.52%, while specificity was 91.38% and 88.85%, respectively. AUC differences vs. the extended clinical model were not statistically significant (DeLong P = 0.758 and P = 0.294, respectively). The publicly released frozen GBM pipeline reproduced stored predictions to numerical precision in 987 participants with complete predictor measurements. Conclusion An eight-indicator GBM demonstrated consistent discrimination across internal and temporal validation cohorts. However, improvement over the extended clinical model was not statistically significant, and sensitivity was limited. Routine laboratory-based models warrant further investigation as potential adjuncts to gynecological assessment. Multicenter external validation and prospective clinical utility evaluation are required before implementation.

Authors

Institutions

Publication Details

Journal
Frontiers in Medicine
Published
2026-11-18
DOI
https://doi.org/10.3389/fmed.2026.1934454
Primary Topic
Endometriosis Research and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Development and temporal validation of a gradient boosting machine model for endometriosis using routine laboratory indicators

Taotao Rong, Guoliu Ye, 胡群, Jie Wei et al.
5 links
Frontiers in Medicine
Endometriosis Research and Treatment
article

Development and temporal validation of a gradient boosting machine model for endometriosis using routine laboratory indicators

Taotao Rong, Guoliu Ye, 胡群, Jie Wei, Ziming Zhao, Shenao Ma, Luyao Wang, Hao Li
article en

Abstract

Background Endometriosis (EM) is a chronic gynecological disorder for which timely diagnosis remains challenging. Routine laboratory indicators may inform EM identification, but their performance in multivariable diagnostic models requires rigorous validation. This study aimed to develop and temporally validate a machine learning model for identifying EM among women undergoing gynecological evaluation. Methods This retrospective, single-center study included 2,452 women (839 with EM and 1,613 disease controls). Participants were allocated to training ( n = 1,029), internal test ( n = 441), and temporal validation ( n = 982) cohorts. Twelve candidate predictors were evaluated using least absolute shrinkage and selection operator regression and Boruta. Six algorithms were compared using repeated nested cross-validation. The selected model underwent discrimination, calibration, exploratory decision curve, clinical comparator, and sensitivity analyses. Results Eight indicators were selected: triglycerides, high-density lipoprotein cholesterol, low-density lipoprotein cholesterol, lymphocyte count, neutrophil count, monocyte count, platelet count, and CA125. Gradient boosting machine (GBM) achieved the highest mean area under the receiver operating characteristic curve (AUC) during repeated nested cross-validation (0.8483). The GBM achieved AUCs of 0.8401 (95% CI, 0.8006–0.8797) internally and 0.8565 (95% CI, 0.8320–0.8810) temporally. At a fixed threshold of 0.50, sensitivity was 55.63% and 59.52%, while specificity was 91.38% and 88.85%, respectively. AUC differences vs. the extended clinical model were not statistically significant (DeLong P = 0.758 and P = 0.294, respectively). The publicly released frozen GBM pipeline reproduced stored predictions to numerical precision in 987 participants with complete predictor measurements. Conclusion An eight-indicator GBM demonstrated consistent discrimination across internal and temporal validation cohorts. However, improvement over the extended clinical model was not statistically significant, and sensitivity was limited. Routine laboratory-based models warrant further investigation as potential adjuncts to gynecological assessment. Multicenter external validation and prospective clinical utility evaluation are required before implementation.

Frontiers in MedicineVol. 13
Bengbu Medical College (CN), First Affiliated Hospital of Bengbu Medical College (CN)
Good health and well-being
Endometriosis Research and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon