Experimental Analysis of Tuned Liquid Dampers with Various Damping Screen Geometries and Porosity Ratios Under Dynamic Excitations

The purpose of this study is to evaluate the vibration control performance of tuned liquid dampers (TLDs) equipped with internal perforated and slat screens. The effect of screen geometry and porosity on nonlinear sloshing and structural response reduction was investigated through a series of shake table tests. Harmonic tests at fixed frequencies and seismic excitations using four scaled earthquake records (El Centro, Kobe, Loma Prieta, and Sakarya) were applied to the test frame. A parametric analysis was performed by varying the water depth (4.5 cm to 6.5 cm) and screen porosity (40%, 50%, 60%). The results indicate that a 40% porosity gave the lowest added damping ratio and response reduction, consistent with overdamping of the sloshing mode, whereas a 60% porosity gave the largest added damping ratio among the screens. At the best tested depth (5.0 cm), screens reduced the peak roof acceleration by up to 27% under the Kobe record, against 17.5% for the plain TLD, but gave no consistent improvement under the other records. The root-mean-square (RMS) roof accelerations, an average measure of the response level over the record, were reduced by up to 49%. The benefit of the screens and the best water depth depend on the input.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2026-11-18
DOI
https://doi.org/10.3390/buildings16224590
Primary Topic
Vibration Control and Rheological Fluids
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Experimental Analysis of Tuned Liquid Dampers with Various Damping Screen Geometries and Porosity Ratios Under Dynamic Excitations

Ali Bozer, Özer Atar
Buildings
Vibration Control and Rheological Fluids
article

Experimental Analysis of Tuned Liquid Dampers with Various Damping Screen Geometries and Porosity Ratios Under Dynamic Excitations

Ali Bozer, Özer Atar
article en

Abstract

The purpose of this study is to evaluate the vibration control performance of tuned liquid dampers (TLDs) equipped with internal perforated and slat screens. The effect of screen geometry and porosity on nonlinear sloshing and structural response reduction was investigated through a series of shake table tests. Harmonic tests at fixed frequencies and seismic excitations using four scaled earthquake records (El Centro, Kobe, Loma Prieta, and Sakarya) were applied to the test frame. A parametric analysis was performed by varying the water depth (4.5 cm to 6.5 cm) and screen porosity (40%, 50%, 60%). The results indicate that a 40% porosity gave the lowest added damping ratio and response reduction, consistent with overdamping of the sloshing mode, whereas a 60% porosity gave the largest added damping ratio among the screens. At the best tested depth (5.0 cm), screens reduced the peak roof acceleration by up to 27% under the Kobe record, against 17.5% for the plain TLD, but gave no consistent improvement under the other records. The root-mean-square (RMS) roof accelerations, an average measure of the response level over the record, were reduced by up to 49%. The benefit of the screens and the best water depth depend on the input.

BuildingsVol. 16(22)
Eskisehir Technical University (TR)
Türkiye Bilimsel ve Teknolojik Araştırma Kurumu
Vibration Control and Rheological Fluids
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon