Prediction of icing tensile load on transmission lines based on BiGRU-informer model fusion and denoising synergy

Accurate prediction of icing-induced comprehensive tension loads on transmission lines is critical for icing disaster warning and safe operation and maintenance. Load sequences are affected by noise, wind-induced vibration, and abrupt meteorological changes, resulting in non-stationary fluctuations, local abrupt changes, and long-term dependencies. To address these issues, this paper proposes an SSA-BiGRU-Informer fusion prediction model. First, singular spectrum analysis (SSA) is used to decompose and reconstruct the historical load series, thereby weakening low-energy disturbances. A bidirectional gated recurrent unit (BiGRU) is then employed to extract local bidirectional temporal features, while Informer is used to capture long-timescale dependencies. Experiments based on online monitoring data from a 220 kV overhead transmission line in Zhejiang Province show that the proposed model achieves RMSE, MAPE, MAE, and R 2 values of 332.46 N, 0.64%, 223.08 N, and 0.94, respectively. Overall, SSA-BiGRU-Informer achieved the lowest mean RMSE, MAPE, and MAE and the highest mean R 2 among the compared models. Paired t-tests with Holm-adjusted p-values further supported significant RMSE improvements over three of the four baseline models. Ablation experiments show that SSA, BiGRU, and Informer contribute to noise suppression, local dynamic feature extraction, and long-range dependency modeling, respectively, verifying the effectiveness of multi-module collaborative modeling. The cross-city and cross-line experiment, conducted during the same one-month period on another overhead transmission line located in a different city within Zhejiang Province, shows that the proposed model also performs well, indicating its applicability to tension-load prediction for icing-disaster warning and stress assessment.

Authors

Institutions

Publication Details

Journal
Measurement and Control
Published
2026-11-18
DOI
https://doi.org/10.1177/00202940261508402
Primary Topic
Icing and De-icing Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Prediction of icing tensile load on transmission lines based on BiGRU-informer model fusion and denoising synergy

Yongkang Peng, Zun Wang, Guoping Zou, Wentong Chen et al.
1 links
Measurement and Control
Icing and De-icing Technologies
article

Prediction of icing tensile load on transmission lines based on BiGRU-informer model fusion and denoising synergy

Yongkang Peng, Zun Wang, Guoping Zou, Wentong Chen, Jiange Jiao, Fanglin Liu, Yuntu Jiang, Shuhao Zhang, Bihui Zhang, Xiaowen Tong
article en

Abstract

Accurate prediction of icing-induced comprehensive tension loads on transmission lines is critical for icing disaster warning and safe operation and maintenance. Load sequences are affected by noise, wind-induced vibration, and abrupt meteorological changes, resulting in non-stationary fluctuations, local abrupt changes, and long-term dependencies. To address these issues, this paper proposes an SSA-BiGRU-Informer fusion prediction model. First, singular spectrum analysis (SSA) is used to decompose and reconstruct the historical load series, thereby weakening low-energy disturbances. A bidirectional gated recurrent unit (BiGRU) is then employed to extract local bidirectional temporal features, while Informer is used to capture long-timescale dependencies. Experiments based on online monitoring data from a 220 kV overhead transmission line in Zhejiang Province show that the proposed model achieves RMSE, MAPE, MAE, and R 2 values of 332.46 N, 0.64%, 223.08 N, and 0.94, respectively. Overall, SSA-BiGRU-Informer achieved the lowest mean RMSE, MAPE, and MAE and the highest mean R 2 among the compared models. Paired t-tests with Holm-adjusted p-values further supported significant RMSE improvements over three of the four baseline models. Ablation experiments show that SSA, BiGRU, and Informer contribute to noise suppression, local dynamic feature extraction, and long-range dependency modeling, respectively, verifying the effectiveness of multi-module collaborative modeling. The cross-city and cross-line experiment, conducted during the same one-month period on another overhead transmission line located in a different city within Zhejiang Province, shows that the proposed model also performs well, indicating its applicability to tension-load prediction for icing-disaster warning and stress assessment.

Measurement and Control
State Grid Corporation of China (China) (CN), Shantui (China) (CN), Shanghai Electric (China) (CN), State Grid Zhejiang Electric Power Company (China) (CN), China Jiliang University (CN)
National Natural Science Foundation of China, State Grid Zhejiang Electric Power Company, Natural Science Foundation of Zhejiang Province
Industry, innovation and infrastructure
Icing and De-icing Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon