On‐Column Focusing Strategies for Large‐Volume Injections in Nano‐Liquid Chromatography: Sample Diluent, Injection Sequence, and Localized Cooling

Sensitivity remains a major limitation of nano-liquid chromatography (nano-LC), where reduced injection volumes and small spectrophotometric detection cells constrain analytical performance relative to conventional HPLC. This work systematically investigated sample on-column focusing strategies to control overloading during large-volume injections in nano-LC without compromising chromatographic resolution and efficiency. Using a model mixture of alkylbenzenes separated on a 100 µm i.d. capillary column packed with a C18 stationary phase in a lab-made nano-LC system, three complementary approaches were evaluated: (i) tuning the sample diluent composition, including aqueous content and the use of conventional and green organic co-solvents (isoamylacetate, 2-methyltetrahydrofuran, and dimethyl carbonate); (ii) injection-sequence strategies based on pre- and post-injection solvent plugs; and (iii) localized low-temperature focusing achieved with an instant cold spray applied at the column inlet immediately before sample injection. Optimizing diluent composition alone enabled a ∼40/60-fold increase in injection volume (up to 600-1000 nL) without loss of efficiency. Adding a post-injection water plug extended this to ∼120/150-fold (2000-2500 nL), improving chromatographic efficiency by up to 30%. When high diluent eluent strength precluded solvent-based focusing, a brief cold-spray application at the column inlet (down to ∼4°C) fully restored resolution, independent of the organic solvent used. These results demonstrate that combining diluent tuning, injection-sequence control, and low-temperature focusing can extend nano-LC injection volumes by nearly two orders of magnitude beyond the theoretical admissible injection volume while preserving separation performance, offering simple, low-cost strategies to improve analytical sensitivity.

Authors

Institutions

Publication Details

Journal
Electrophoresis
Published
2026-11-18
DOI
https://doi.org/10.1002/elps.70185
Primary Topic
Analytical Chemistry and Chromatography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

On‐Column Focusing Strategies for Large‐Volume Injections in Nano‐Liquid Chromatography: Sample Diluent, Injection Sequence, and Localized Cooling

Giovanni Tiso D'Orazio, Salvatore Fanali
Electrophoresis
Analytical Chemistry and Chromatography
article

On‐Column Focusing Strategies for Large‐Volume Injections in Nano‐Liquid Chromatography: Sample Diluent, Injection Sequence, and Localized Cooling

Giovanni Tiso D'Orazio, Salvatore Fanali
article en

Abstract

Sensitivity remains a major limitation of nano-liquid chromatography (nano-LC), where reduced injection volumes and small spectrophotometric detection cells constrain analytical performance relative to conventional HPLC. This work systematically investigated sample on-column focusing strategies to control overloading during large-volume injections in nano-LC without compromising chromatographic resolution and efficiency. Using a model mixture of alkylbenzenes separated on a 100 µm i.d. capillary column packed with a C18 stationary phase in a lab-made nano-LC system, three complementary approaches were evaluated: (i) tuning the sample diluent composition, including aqueous content and the use of conventional and green organic co-solvents (isoamylacetate, 2-methyltetrahydrofuran, and dimethyl carbonate); (ii) injection-sequence strategies based on pre- and post-injection solvent plugs; and (iii) localized low-temperature focusing achieved with an instant cold spray applied at the column inlet immediately before sample injection. Optimizing diluent composition alone enabled a ∼40/60-fold increase in injection volume (up to 600-1000 nL) without loss of efficiency. Adding a post-injection water plug extended this to ∼120/150-fold (2000-2500 nL), improving chromatographic efficiency by up to 30%. When high diluent eluent strength precluded solvent-based focusing, a brief cold-spray application at the column inlet (down to ∼4°C) fully restored resolution, independent of the organic solvent used. These results demonstrate that combining diluent tuning, injection-sequence control, and low-temperature focusing can extend nano-LC injection volumes by nearly two orders of magnitude beyond the theoretical admissible injection volume while preserving separation performance, offering simple, low-cost strategies to improve analytical sensitivity.

Electrophoresis
Tbilisi State University (GE), National Research Council (IT)
Analytical Chemistry and Chromatography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon