BEER editable checklist and linked records

This record provides an editable implementation package for the Bioelectronic Electrode Evaluation and Reporting (BEER) framework, supporting the planning, reporting and appraisal of non-invasive skin-interfacing biopotential electrode evaluations. It covers conventional and soft electrodes used for electrocardiography (ECG), surface electromyography (EMG) and electroencephalography (EEG). The package contains: • An editable blank checklist comprising 36 BEER items, with applicability rules, response fields, defined status values and preserved item identifiers. • Linked-record templates for documenting intended claims, evaluation conditions, evidence sources, measurements, missing information, governance requirements and justified conclusions. • A completed constructed ECG demonstration associated with Section 9.2 of the accompanying manuscript, explicitly distinguishing stipulated inputs, missing measurements and not-applicable items. • Arithmetic reference values and worked calculations illustrating interval-based monitoring metrics and optional scoring and sensitivity analyses. The framework connects intended claims to applicable tests, interpretable measurements, evidence requirements, reporting and justified conclusions. Particular attention is given to measurement topology, acquisition loading and the distinction between conditional signal yield, scheduled-time monitoring availability and physiological correctness. All demonstration inputs are stipulated. The package contains no new experimental measurements or participant-level data. The constructed examples illustrate reporting and accounting procedures; they do not establish electrode performance or validate a signal-quality algorithm. BEER is a proposed methodological framework and reporting checklist, not a consensus standard, an empirically validated quality scale or evidence of regulatory conformity. The package accompanies the manuscript “A Practical Framework for Characterizing and Validating Skin-Interfacing Biopotential Electrodes” by Manuel Reis Carneiro. Release identification: checklist version 0.1; implementation package revision 3, prepared 15 November 2026. The checklist version identifies the reporting specification; the package revision identifies the implementation document. The original checklist, templates and constructed examples are released under the Creative Commons Attribution 4.0 International licence (CC BY 4.0).

Authors

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-18
DOI
https://doi.org/10.5281/zenodo.24250413
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

BEER editable checklist and linked records

Manuel Reis Carneiro
Zenodo (CERN European Organization for Nuclear Research)
ECG Monitoring and Analysis
article

BEER editable checklist and linked records

Manuel Reis Carneiro
article en

Abstract

This record provides an editable implementation package for the Bioelectronic Electrode Evaluation and Reporting (BEER) framework, supporting the planning, reporting and appraisal of non-invasive skin-interfacing biopotential electrode evaluations. It covers conventional and soft electrodes used for electrocardiography (ECG), surface electromyography (EMG) and electroencephalography (EEG). The package contains: • An editable blank checklist comprising 36 BEER items, with applicability rules, response fields, defined status values and preserved item identifiers. • Linked-record templates for documenting intended claims, evaluation conditions, evidence sources, measurements, missing information, governance requirements and justified conclusions. • A completed constructed ECG demonstration associated with Section 9.2 of the accompanying manuscript, explicitly distinguishing stipulated inputs, missing measurements and not-applicable items. • Arithmetic reference values and worked calculations illustrating interval-based monitoring metrics and optional scoring and sensitivity analyses. The framework connects intended claims to applicable tests, interpretable measurements, evidence requirements, reporting and justified conclusions. Particular attention is given to measurement topology, acquisition loading and the distinction between conditional signal yield, scheduled-time monitoring availability and physiological correctness. All demonstration inputs are stipulated. The package contains no new experimental measurements or participant-level data. The constructed examples illustrate reporting and accounting procedures; they do not establish electrode performance or validate a signal-quality algorithm. BEER is a proposed methodological framework and reporting checklist, not a consensus standard, an empirically validated quality scale or evidence of regulatory conformity. The package accompanies the manuscript “A Practical Framework for Characterizing and Validating Skin-Interfacing Biopotential Electrodes” by Manuel Reis Carneiro. Release identification: checklist version 0.1; implementation package revision 3, prepared 15 November 2026. The checklist version identifies the reporting specification; the package revision identifies the implementation document. The original checklist, templates and constructed examples are released under the Creative Commons Attribution 4.0 International licence (CC BY 4.0).

Zenodo (CERN European Organization for Nuclear Research)
ETH Zurich (CH)
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon