Experimental thermo-electrical assessment of water-cooled and PCM-assisted photovoltaic thermal systems under hot climatic conditions

This study experimentally investigates the thermo-electrical and thermodynamic performance of water-cooled photovoltaic thermal (PVT-water) and phase change material-assisted photovoltaic thermal (PVT-PCM) systems operating under hot climatic conditions in Cairo, Egypt. The PVT-PCM system incorporated encapsulated RT35 paraffin wax within a water-cooling channel, while the PVT-water system employed three different copper absorber configurations. Both systems were tested at flow rates of 2 and 3 L/min under insulated and non-insulated conditions. The results showed that both cooling approaches significantly improved photovoltaic performance compared with the reference uncooled PV module. However, the PVT-PCM system consistently achieved superior thermal regulation through the combined effects of active water cooling and latent heat storage. The maximum PV temperature reduction reached 6.5 °C for the PVT-PCM system compared with 4.9 °C for the PVT-water configuration. Consequently, the PVT-PCM system improved electrical power generation by up to 23.6%, while the PVT-water system achieved improvements of approximately 11%. The highest thermal and overall efficiencies obtained for the PVT-PCM system were 62.5% and 76.5%, respectively, compared with 59.3% and 72.4% for the PVT-water system. In addition, exergy analysis confirmed improved thermodynamic performance for the PCM-assisted configuration due to enhanced thermal regulation and reduced thermal irreversibility. The findings demonstrate that integrating encapsulated phase change material with active water cooling provides an effective hybrid thermal management strategy for photovoltaic thermal systems operating in hot climates, resulting in significant improvements in thermal regulation, energy recovery, and overall system performance.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-11-18
DOI
https://doi.org/10.1038/s41598-026-73086-6
Primary Topic
Solar Thermal and Photovoltaic Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Experimental thermo-electrical assessment of water-cooled and PCM-assisted photovoltaic thermal systems under hot climatic conditions

Mohamed Emam, Bandar Awadh Almohammadi, Abdullah M. A. Alsharif, H. A. Refaey et al.
1 links
Scientific Reports
Solar Thermal and Photovoltaic Systems
article

Experimental thermo-electrical assessment of water-cooled and PCM-assisted photovoltaic thermal systems under hot climatic conditions

Mohamed Emam, Bandar Awadh Almohammadi, Abdullah M. A. Alsharif, H. A. Refaey, M. A. Abdelrahman
article en

Abstract

This study experimentally investigates the thermo-electrical and thermodynamic performance of water-cooled photovoltaic thermal (PVT-water) and phase change material-assisted photovoltaic thermal (PVT-PCM) systems operating under hot climatic conditions in Cairo, Egypt. The PVT-PCM system incorporated encapsulated RT35 paraffin wax within a water-cooling channel, while the PVT-water system employed three different copper absorber configurations. Both systems were tested at flow rates of 2 and 3 L/min under insulated and non-insulated conditions. The results showed that both cooling approaches significantly improved photovoltaic performance compared with the reference uncooled PV module. However, the PVT-PCM system consistently achieved superior thermal regulation through the combined effects of active water cooling and latent heat storage. The maximum PV temperature reduction reached 6.5 °C for the PVT-PCM system compared with 4.9 °C for the PVT-water configuration. Consequently, the PVT-PCM system improved electrical power generation by up to 23.6%, while the PVT-water system achieved improvements of approximately 11%. The highest thermal and overall efficiencies obtained for the PVT-PCM system were 62.5% and 76.5%, respectively, compared with 59.3% and 72.4% for the PVT-water system. In addition, exergy analysis confirmed improved thermodynamic performance for the PCM-assisted configuration due to enhanced thermal regulation and reduced thermal irreversibility. The findings demonstrate that integrating encapsulated phase change material with active water cooling provides an effective hybrid thermal management strategy for photovoltaic thermal systems operating in hot climates, resulting in significant improvements in thermal regulation, energy recovery, and overall system performance.

Scientific Reports
Benha University (EG), Taibah University (SA), University of Bisha (SA)
Affordable and clean energy, Climate action, Industry, innovation and infrastructure
Solar Thermal and Photovoltaic Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon