Portable optical coherence tomography for monitoring artificial dermal scaffold integration: a murine and clinical study

Aim: To develop a handheld swept-source optical coherence tomography (SS-OCT) system, assess the correspondence between OCT and histological findings in murine wounds, and evaluate its clinical applicability in patients treated with artificial dermal scaffolds. Methods: A full-thickness wound model was established in 30 male ICR mice. Lando artificial dermal scaffolds or autologous skin grafts were implanted with or without basic fibroblast growth factor (bFGF). Structural brightness-scan (B-scan) images and en face optical coherence tomography (OCT) angiographic projections were acquired longitudinally and compared with hematoxylin and eosin (H&E) staining and cluster of differentiation 31 (CD31, platelet endothelial cell adhesion molecule-1) immunohistochemistry. Clinical validation included five patients with full-thickness skin defects reconstructed using bilayer Lando scaffolds. Serial SS-OCT findings were compared with H&E staining and cluster of differentiation 34 (CD34) immunohistochemistry. The collagen sponge layer was segmented to calculate the Index of Scaffold Ingrowth, Vascularization and Degradation (IRDR) from the relative reduction in volume. Results: In mice, OCT features corresponded to sequential histological changes, from inflammatory infiltration to matrix formation and neovascularization. The bFGF-treated scaffold group showed earlier and more pronounced vascular signals. In patients, SS-OCT images showed close visual agreement with histopathological findings, and the estimated IRDR of the collagen sponge layer increased progressively during follow-up. Conclusion: Portable SS-OCT provides repeatable, non-invasive in vivo structural and vascular imaging that corresponds to histological findings in murine and human wounds. SS-OCT shows promise for longitudinal monitoring of artificial dermal scaffold integration and may help optimize dressing-change intervals and the timing of second-stage grafting.

Authors

Institutions

Publication Details

Journal
Plastic and Aesthetic Research
Published
2026-11-18
DOI
https://doi.org/10.20517/2347-9264.2026.121
Primary Topic
Optical Coherence Tomography Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Portable optical coherence tomography for monitoring artificial dermal scaffold integration: a murine and clinical study

Zhiyang Ren, Yasen Cui, Jianhua Mo, Shuhan Tang et al.
1 links
Plastic and Aesthetic Research
Optical Coherence Tomography Applications
article

Portable optical coherence tomography for monitoring artificial dermal scaffold integration: a murine and clinical study

Zhiyang Ren, Yasen Cui, Jianhua Mo, Shuhan Tang, Yao Xu, Ke Li
article en

Abstract

Aim: To develop a handheld swept-source optical coherence tomography (SS-OCT) system, assess the correspondence between OCT and histological findings in murine wounds, and evaluate its clinical applicability in patients treated with artificial dermal scaffolds. Methods: A full-thickness wound model was established in 30 male ICR mice. Lando artificial dermal scaffolds or autologous skin grafts were implanted with or without basic fibroblast growth factor (bFGF). Structural brightness-scan (B-scan) images and en face optical coherence tomography (OCT) angiographic projections were acquired longitudinally and compared with hematoxylin and eosin (H&E) staining and cluster of differentiation 31 (CD31, platelet endothelial cell adhesion molecule-1) immunohistochemistry. Clinical validation included five patients with full-thickness skin defects reconstructed using bilayer Lando scaffolds. Serial SS-OCT findings were compared with H&E staining and cluster of differentiation 34 (CD34) immunohistochemistry. The collagen sponge layer was segmented to calculate the Index of Scaffold Ingrowth, Vascularization and Degradation (IRDR) from the relative reduction in volume. Results: In mice, OCT features corresponded to sequential histological changes, from inflammatory infiltration to matrix formation and neovascularization. The bFGF-treated scaffold group showed earlier and more pronounced vascular signals. In patients, SS-OCT images showed close visual agreement with histopathological findings, and the estimated IRDR of the collagen sponge layer increased progressively during follow-up. Conclusion: Portable SS-OCT provides repeatable, non-invasive in vivo structural and vascular imaging that corresponds to histological findings in murine and human wounds. SS-OCT shows promise for longitudinal monitoring of artificial dermal scaffold integration and may help optimize dressing-change intervals and the timing of second-stage grafting.

Plastic and Aesthetic Research
Soochow University (CN), First Affiliated Hospital of Soochow University (CN)
Good health and well-being
Optical Coherence Tomography Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon