Distributed model predictive control with adaptive virtual impedance for power sharing and voltage–frequency regulation in AC microgrids

Accurate power sharing and voltage/frequency regulation are essential for islanded AC microgrids. Unequal feeder impedances and the coupled effects of impedance adjustment, however, make these objectives difficult to coordinate. This paper proposes a distributed model predictive control (DMPC)-based adaptive virtual-impedance strategy for common-bus AC microgrids with predominantly resistive feeders. A coupled fundamental-power predictor links virtual-resistance and virtual-reactance increments to active- and reactive-power redistribution, allowing each distributed energy resource (DER) to jointly optimize both increments for power tracking and sharing. The distributed receding-horizon optimization incorporates adjustment effort, impedance bounds and a sign-dependent linear approximation of predicted apparent-power constraints. Combined with reverse droop and average-voltage restoration, the strategy coordinates active/reactive power sharing and voltage/frequency regulation without a dedicated secondary frequency-restoration loop. OPAL-RT real-time tests demonstrate coordinated operation under load changes, communication-link outage and DER plug-and-play. Extended tests demonstrate robust power sharing and voltage/frequency regulation under variable delays, random packet losses, asynchronous information exchange and short simultaneous link interruptions. In load-change comparisons, reactive-power steady-state error is reduced by 2.6% and 4.6% relative to the DMPC and DAPI-inspired baselines, respectively. Active-power convergence is shortened by 3.67 s relative to DMPC, while reactive-power overshoot is reduced by 17.8% relative to the DAPI-inspired baseline. The later-stage reactive-sharing benefit is retained under a changed load composition without further tuning. Parameter assessments guide weight and horizon selection, while six- and nine-DER cases retain coordinated operation with similar typical per-DER solver times at fixed horizon and neighbor degree.

Authors

Institutions

Publication Details

Journal
Sustainable Energy Technologies and Assessments
Published
2026-11-18
DOI
https://doi.org/10.1016/j.seta.2026.105592
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Distributed model predictive control with adaptive virtual impedance for power sharing and voltage–frequency regulation in AC microgrids

Yunzhu Cao, Siyuan Cheng, Yajie Jiang, Akshya Kumar Swain et al.
1 links
Sustainable Energy Technologies and Assessments
Microgrid Control and Optimization
article

Distributed model predictive control with adaptive virtual impedance for power sharing and voltage–frequency regulation in AC microgrids

Yunzhu Cao, Siyuan Cheng, Yajie Jiang, Akshya Kumar Swain, Abhisek Ukil, Haoze Wang, Guangze Sun
article en

Abstract

Accurate power sharing and voltage/frequency regulation are essential for islanded AC microgrids. Unequal feeder impedances and the coupled effects of impedance adjustment, however, make these objectives difficult to coordinate. This paper proposes a distributed model predictive control (DMPC)-based adaptive virtual-impedance strategy for common-bus AC microgrids with predominantly resistive feeders. A coupled fundamental-power predictor links virtual-resistance and virtual-reactance increments to active- and reactive-power redistribution, allowing each distributed energy resource (DER) to jointly optimize both increments for power tracking and sharing. The distributed receding-horizon optimization incorporates adjustment effort, impedance bounds and a sign-dependent linear approximation of predicted apparent-power constraints. Combined with reverse droop and average-voltage restoration, the strategy coordinates active/reactive power sharing and voltage/frequency regulation without a dedicated secondary frequency-restoration loop. OPAL-RT real-time tests demonstrate coordinated operation under load changes, communication-link outage and DER plug-and-play. Extended tests demonstrate robust power sharing and voltage/frequency regulation under variable delays, random packet losses, asynchronous information exchange and short simultaneous link interruptions. In load-change comparisons, reactive-power steady-state error is reduced by 2.6% and 4.6% relative to the DMPC and DAPI-inspired baselines, respectively. Active-power convergence is shortened by 3.67 s relative to DMPC, while reactive-power overshoot is reduced by 17.8% relative to the DAPI-inspired baseline. The later-stage reactive-sharing benefit is retained under a changed load composition without further tuning. Parameter assessments guide weight and horizon selection, while six- and nine-DER cases retain coordinated operation with similar typical per-DER solver times at fixed horizon and neighbor degree.

Sustainable Energy Technologies and AssessmentsVol. 96
University of Auckland (NZ), Nanyang Technological University (SG)
Industry, innovation and infrastructure, Affordable and clean energy
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon