Prosthetic maintenance and complications of single implant-retained mandibular overdentures: a systematic review

Prosthetic maintenance and mechanical complications of single implant-retained mandibular overdentures have not been fully summarised. In this PROSPERO-registered review (CRD420261422355), seven sources were searched on 17 October 2026, followed by citation searching in OpenAlex. Trials and cohorts of edentulous adults with one midline mandibular implant retaining an overdenture and at least 12 months of follow-up after loading were eligible. Two reviewers independently selected studies, extracted data and assessed risk of bias (RoB 2, MINORS). Synthesis was without meta-analysis; certainty was rated with GRADE. Sixty-eight reports of 41 studies (27 randomised trials, 14 cohorts; 1,157 participants; 12 months to 15 years) were included. No trial had low risk of bias. No implant was lost after loading in 16 of 21 studies with conventional or early loading; in the only trial randomising loading, 9 of 81 immediately and 2 of 77 conventionally loaded implants failed. Retention-element maintenance was most frequent: 76 of 102 and 23 of 29 patients needed adjustment over 5 years in two trials. Fractures of unreinforced dentures, mostly next to the attachment, affected 27 of 102 to 6 of 11 patients over 5 to 15 years; three small studies of reinforced dentures reported none. All outcomes had low or very-low certainty. These overdentures had few implant losses after conventional or early loading but frequent retention-element maintenance and fractures of unreinforced dentures. Metal reinforcement and delayed loading may reduce the risk of mechanical complications, but the evidence is of low to very low certainty. PROSPERO CRD420261422355.

Authors

Institutions

Publication Details

Journal
BMC Oral Health
Published
2026-11-18
DOI
https://doi.org/10.1186/s12903-026-10382-7
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Prosthetic maintenance and complications of single implant-retained mandibular overdentures: a systematic review

Kapil Hazarika, Kadambari Bharali, Nilutpal Deuri
BMC Oral Health
Dental Implant Techniques and Outcomes
article

Prosthetic maintenance and complications of single implant-retained mandibular overdentures: a systematic review

Kapil Hazarika, Kadambari Bharali, Nilutpal Deuri
article en

Abstract

Prosthetic maintenance and mechanical complications of single implant-retained mandibular overdentures have not been fully summarised. In this PROSPERO-registered review (CRD420261422355), seven sources were searched on 17 October 2026, followed by citation searching in OpenAlex. Trials and cohorts of edentulous adults with one midline mandibular implant retaining an overdenture and at least 12 months of follow-up after loading were eligible. Two reviewers independently selected studies, extracted data and assessed risk of bias (RoB 2, MINORS). Synthesis was without meta-analysis; certainty was rated with GRADE. Sixty-eight reports of 41 studies (27 randomised trials, 14 cohorts; 1,157 participants; 12 months to 15 years) were included. No trial had low risk of bias. No implant was lost after loading in 16 of 21 studies with conventional or early loading; in the only trial randomising loading, 9 of 81 immediately and 2 of 77 conventionally loaded implants failed. Retention-element maintenance was most frequent: 76 of 102 and 23 of 29 patients needed adjustment over 5 years in two trials. Fractures of unreinforced dentures, mostly next to the attachment, affected 27 of 102 to 6 of 11 patients over 5 to 15 years; three small studies of reinforced dentures reported none. All outcomes had low or very-low certainty. These overdentures had few implant losses after conventional or early loading but frequent retention-element maintenance and fractures of unreinforced dentures. Metal reinforcement and delayed loading may reduce the risk of mechanical complications, but the evidence is of low to very low certainty. PROSPERO CRD420261422355.

BMC Oral Health
Atal Bihari Vajpayee Institute of Medical Sciences and Dr. Ram Manohar Lohia Hospital (IN), Regional Medical Research Centre (IN), Assam Medical College (IN)
Good health and well-being
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.