Fluid–structure interaction–driven pressure regulation in a membrane-based hydrocephalus shunt valve

Passive flow regulation through fluid–structure interaction (FSI) offers a promising strategy for controlling pressure-driven flows in compliant microvalves. In cerebrospinal fluid (CSF) ventriculoperitoneal shunt systems, posture-dependent siphoning remains a major challenge and is typically mitigated using additional anti-siphon components, which increase device complexity and implantation footprint. In this work, we investigate how deformation of a pre-tensioned compliant membrane can intrinsically regulate hydraulic resistance under varying distal pressure conditions. The proposed valve concept modulates the proximal valve inlet pressure through the deformation of a single membrane that responds to the pressure difference across the valve, enabling the device to establish a baseline operating pressure while counteracting posture-related overdrainage by modulating the effective flow resistance. Valve behavior was analyzed using fully coupled numerical FSI simulations and experimentally evaluated using 2:1 scaled prototypes tested in a hydrostatic benchtop flow loop. Experiments conducted at equivalent real-scale CSF flow rates under controlled distal-pressure conditions representing supine and upright test configurations showed strong qualitative agreement with numerical predictions. Under the distal suction condition associated with upright posture, membrane–seat interaction produced an increase in the proximal valve inlet pressure required to sustain the same imposed flow, reflecting an increase in hydraulic resistance that opposes siphoning-driven overdrainage. Importantly, the pressure response remained weakly dependent on flow rate across the investigated range, while distinct operating regimes could be achieved by adjusting membrane pre-tension. Although the implications of this valve-level behavior for physiological intracranial pressure (ICP) require further evaluation in complete shunt systems, the results highlight the potential of intrinsic FSI-based resistance modulation for passive pressure regulation. This approach offers a promising route toward compact hydrocephalus shunt valves with integrated anti-siphon functionality, with broader potential applications in compliant biofluidic control systems.

Authors

Institutions

Publication Details

Journal
Journal of Fluids and Structures
Published
2026-11-18
DOI
https://doi.org/10.1016/j.jfluidstructs.2026.104753
Primary Topic
Cerebrospinal fluid and hydrocephalus
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Fluid–structure interaction–driven pressure regulation in a membrane-based hydrocephalus shunt valve

Soroush Rafiei, Nikolaos Stergiopulos
Journal of Fluids and Structures
Cerebrospinal fluid and hydrocephalus
article

Fluid–structure interaction–driven pressure regulation in a membrane-based hydrocephalus shunt valve

Soroush Rafiei, Nikolaos Stergiopulos
article en

Abstract

Passive flow regulation through fluid–structure interaction (FSI) offers a promising strategy for controlling pressure-driven flows in compliant microvalves. In cerebrospinal fluid (CSF) ventriculoperitoneal shunt systems, posture-dependent siphoning remains a major challenge and is typically mitigated using additional anti-siphon components, which increase device complexity and implantation footprint. In this work, we investigate how deformation of a pre-tensioned compliant membrane can intrinsically regulate hydraulic resistance under varying distal pressure conditions. The proposed valve concept modulates the proximal valve inlet pressure through the deformation of a single membrane that responds to the pressure difference across the valve, enabling the device to establish a baseline operating pressure while counteracting posture-related overdrainage by modulating the effective flow resistance. Valve behavior was analyzed using fully coupled numerical FSI simulations and experimentally evaluated using 2:1 scaled prototypes tested in a hydrostatic benchtop flow loop. Experiments conducted at equivalent real-scale CSF flow rates under controlled distal-pressure conditions representing supine and upright test configurations showed strong qualitative agreement with numerical predictions. Under the distal suction condition associated with upright posture, membrane–seat interaction produced an increase in the proximal valve inlet pressure required to sustain the same imposed flow, reflecting an increase in hydraulic resistance that opposes siphoning-driven overdrainage. Importantly, the pressure response remained weakly dependent on flow rate across the investigated range, while distinct operating regimes could be achieved by adjusting membrane pre-tension. Although the implications of this valve-level behavior for physiological intracranial pressure (ICP) require further evaluation in complete shunt systems, the results highlight the potential of intrinsic FSI-based resistance modulation for passive pressure regulation. This approach offers a promising route toward compact hydrocephalus shunt valves with integrated anti-siphon functionality, with broader potential applications in compliant biofluidic control systems.

Journal of Fluids and StructuresVol. 148
École Polytechnique Fédérale de Lausanne (CH)
Good health and well-being
Cerebrospinal fluid and hydrocephalus
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon