Preprint of a manuscript submitted to IEEE Transactions on Energy Conversion. The PDF contains the paper (10 pages) and its supplement (6 pages). Code, OpenFAST inputs and results: https://doi.org/10.5281/zenodo.24327563 Grid-forming wind turbines step power at frequency events and phase jumps; a generator torque that follows excites lightly damped modes: shaft modes in geared, blade modes in direct-drive turbines. Shaped torque delivers energy late, which DC-side storage must bridge; we bound it whatever the mode: for one mode of period T_n, at least ΔP·T_n/4 when the torque only rises and ΔP·T_n/6 when it may fall back without modal overshoot, with optimal trajectories, extended to frequency uncertainty and two modes, ΔP/(f1 + f2) for a rising torque. Where quasi-static and modal loads oppose, as outboard on a one-mode blade, shaped torque still takes the load beyond its initial and final values; a linear programme minimizes the buffer for a bounded excursion. OpenFAST residuals agree within 0.02 for 18 shapers on a one-mode blade and within 0.034 on a geared turbine's shaft unless a pitch limit re-excites it. A geometrically exact blade adds a 3.1-Hz mode; a two-mode design reduces both below a tenth, also at 22 MW; robust designs hold residuals near 10% under 10–15% frequency errors, from 9 to 18 m/s and, against a ramp, in turbulence. Measured and converter-model buffers exceed the design by up to 10%. For the IEA 15-MW turbine's firm inertia of 1.12 s, vibration-free delivery needs 20–30 ms of rated power: 81 supercapacitor modules for its 0.9-MW peak. On this direct-drive turbine shaping addresses repeated events, not strength: the unshaped step adds up to 46% to the largest edgewise moment at 88% span but 9% to the blade's largest edgewise strain.

Authors

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-18
DOI
https://doi.org/10.5281/zenodo.24330689
Primary Topic
Wind Turbine Control Systems
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

How Much DC-Link Energy Does Vibration-Free Inertia From a Grid-Forming Wind Turbine Need?

Yuan Shen
5 links
Zenodo (CERN European Organization for Nuclear Research)
Wind Turbine Control Systems
preprint

How Much DC-Link Energy Does Vibration-Free Inertia From a Grid-Forming Wind Turbine Need?

Yuan Shen
preprint en

Abstract

Preprint of a manuscript submitted to IEEE Transactions on Energy Conversion. The PDF contains the paper (10 pages) and its supplement (6 pages). Code, OpenFAST inputs and results: https://doi.org/10.5281/zenodo.24327563 Grid-forming wind turbines step power at frequency events and phase jumps; a generator torque that follows excites lightly damped modes: shaft modes in geared, blade modes in direct-drive turbines. Shaped torque delivers energy late, which DC-side storage must bridge; we bound it whatever the mode: for one mode of period T_n, at least ΔP·T_n/4 when the torque only rises and ΔP·T_n/6 when it may fall back without modal overshoot, with optimal trajectories, extended to frequency uncertainty and two modes, ΔP/(f1 + f2) for a rising torque. Where quasi-static and modal loads oppose, as outboard on a one-mode blade, shaped torque still takes the load beyond its initial and final values; a linear programme minimizes the buffer for a bounded excursion. OpenFAST residuals agree within 0.02 for 18 shapers on a one-mode blade and within 0.034 on a geared turbine's shaft unless a pitch limit re-excites it. A geometrically exact blade adds a 3.1-Hz mode; a two-mode design reduces both below a tenth, also at 22 MW; robust designs hold residuals near 10% under 10–15% frequency errors, from 9 to 18 m/s and, against a ramp, in turbulence. Measured and converter-model buffers exceed the design by up to 10%. For the IEA 15-MW turbine's firm inertia of 1.12 s, vibration-free delivery needs 20–30 ms of rated power: 81 supercapacitor modules for its 0.9-MW peak. On this direct-drive turbine shaping addresses repeated events, not strength: the unshaped step adds up to 46% to the largest edgewise moment at 88% span but 9% to the blade's largest edgewise strain.

Zenodo (CERN European Organization for Nuclear Research)
University of British Columbia, Okanagan Campus (CA)
Affordable and clean energy, Industry, innovation and infrastructure
Wind Turbine Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon