Static, Dynamic and Robotic CAIS in Healed Partially Edentulous Sites: Accuracy and Chair‐Side Time

AIM: To evaluate the accuracy and chair-side efficiency of static (s-CAIS), dynamic (d-CAIS), and autonomous robotic (r-CAIS) computer-assisted implant surgery in healed partially edentulous sites. MATERIALS AND METHODS: In this retrospective comparative study, 73 patients with 92 implants, treated from September 2022 to October 2024, were included (s-CAIS: 21 patients/33 implants; d-CAIS: 29 patients/32 implants; r-CAIS: 23 patients/27 implants). Pre- and postoperative CBCT scans were used to assess linear and angular deviations. The duration of chair-side preparation and drilling/implant placement was recorded for d-CAIS and r-CAIS. RESULTS: At implant level, mean platform deviations were 0.85 ± 0.38 mm (s-CAIS), 1.37 ± 0.71 mm (d-CAIS), and 0.59 ± 0.32 mm (r-CAIS; median [IQR]: 0.54 [0.30] mm); apex deviations were 1.36 ± 0.51, 1.48 ± 0.66, and 0.64 ± 0.52 mm (r-CAIS; median [IQR]: 0.53 [0.30] mm); angular deviations were 4.34° ± 2.13°, 2.53° ± 0.99°, and 1.54° ± 1.50° (r-CAIS; median [IQR]: 1.28° [1.40°]). At patient level, platform deviations were 0.88 ± 0.35, 1.37 ± 0.69, and 0.57 ± 0.29 mm; apex deviations 1.38 ± 0.44, 1.48 ± 0.65, and 0.58 ± 0.43 mm; angular deviations 4.48° ± 1.81°, 2.52° ± 0.97°, and 1.45° ± 1.30°. r-CAIS showed significantly superior accuracy compared with s-CAIS and d-CAIS (p < 0.05). Because r-CAIS data were not normally distributed, medians [IQR] were additionally calculated and are reported parenthetically. Drilling and placement time was longer for d-CAIS than r-CAIS (18.06 ± 5.54 vs. 10.81 ± 3.55 min, p < 0.05), while chair-side preparatory time did not differ (10.78 ± 2.53 vs. 9.61 ± 2.72 min, p > 0.05). CONCLUSIONS: Among the three systems, r-CAIS provided the highest accuracy and was more time-efficient during the intra-operative (chair-side) phase than d-CAIS in partially edentulous patients. CLINICAL RELEVANCE: In patients with partial edentulism, r-CAIS demonstrated superior accuracy compared with both s-CAIS and d-CAIS approaches. Furthermore, r-CAIS offered greater chair-side efficiency during the intra-operative phase than d-CAIS. This cutting-edge technology holds great promise for enhancing the precision of dental implant procedures, offering substantial benefits to both surgeons and patients.

Authors

Institutions

Publication Details

Journal
Clinical Implant Dentistry and Related Research
Published
2026-11-17
DOI
https://doi.org/10.1111/cid.70201
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Static, Dynamic and Robotic CAIS in Healed Partially Edentulous Sites: Accuracy and Chair‐Side Time

Xiaohui Rausch‐Fan, 赵旭, Feifei Ma, Tao Yu et al.
Clinical Implant Dentistry and Related Research
Dental Implant Techniques and Outcomes
article

Static, Dynamic and Robotic CAIS in Healed Partially Edentulous Sites: Accuracy and Chair‐Side Time

Xiaohui Rausch‐Fan, 赵旭, Feifei Ma, Tao Yu, MiaoZhen Wang, Feng Liu
article en

Abstract

AIM: To evaluate the accuracy and chair-side efficiency of static (s-CAIS), dynamic (d-CAIS), and autonomous robotic (r-CAIS) computer-assisted implant surgery in healed partially edentulous sites. MATERIALS AND METHODS: In this retrospective comparative study, 73 patients with 92 implants, treated from September 2022 to October 2024, were included (s-CAIS: 21 patients/33 implants; d-CAIS: 29 patients/32 implants; r-CAIS: 23 patients/27 implants). Pre- and postoperative CBCT scans were used to assess linear and angular deviations. The duration of chair-side preparation and drilling/implant placement was recorded for d-CAIS and r-CAIS. RESULTS: At implant level, mean platform deviations were 0.85 ± 0.38 mm (s-CAIS), 1.37 ± 0.71 mm (d-CAIS), and 0.59 ± 0.32 mm (r-CAIS; median [IQR]: 0.54 [0.30] mm); apex deviations were 1.36 ± 0.51, 1.48 ± 0.66, and 0.64 ± 0.52 mm (r-CAIS; median [IQR]: 0.53 [0.30] mm); angular deviations were 4.34° ± 2.13°, 2.53° ± 0.99°, and 1.54° ± 1.50° (r-CAIS; median [IQR]: 1.28° [1.40°]). At patient level, platform deviations were 0.88 ± 0.35, 1.37 ± 0.69, and 0.57 ± 0.29 mm; apex deviations 1.38 ± 0.44, 1.48 ± 0.65, and 0.58 ± 0.43 mm; angular deviations 4.48° ± 1.81°, 2.52° ± 0.97°, and 1.45° ± 1.30°. r-CAIS showed significantly superior accuracy compared with s-CAIS and d-CAIS (p < 0.05). Because r-CAIS data were not normally distributed, medians [IQR] were additionally calculated and are reported parenthetically. Drilling and placement time was longer for d-CAIS than r-CAIS (18.06 ± 5.54 vs. 10.81 ± 3.55 min, p < 0.05), while chair-side preparatory time did not differ (10.78 ± 2.53 vs. 9.61 ± 2.72 min, p > 0.05). CONCLUSIONS: Among the three systems, r-CAIS provided the highest accuracy and was more time-efficient during the intra-operative (chair-side) phase than d-CAIS in partially edentulous patients. CLINICAL RELEVANCE: In patients with partial edentulism, r-CAIS demonstrated superior accuracy compared with both s-CAIS and d-CAIS approaches. Furthermore, r-CAIS offered greater chair-side efficiency during the intra-operative phase than d-CAIS. This cutting-edge technology holds great promise for enhancing the precision of dental implant procedures, offering substantial benefits to both surgeons and patients.

Clinical Implant Dentistry and Related ResearchVol. 28(6)
Peking University (CN), Peking University School and Hospital of Stomatology (CN), Medical University of Vienna (AT)
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon