The Timing of Transfusion: Investigating Associations Between Intraoperative Blood Products and Flap Complications in Lower Extremity Free Tissue Reconstruction

BACKGROUND: Microsurgical free flap reconstruction is pivotal for managing complex lower extremity (LE) defects. Although perioperative blood transfusions are frequently employed to manage anemia and hemodynamic stability, their impact on free flap outcomes, specifically related to timing, remains inadequately understood. This study examines how transfusion timing (preoperative, intraoperative, and postoperative) influences flap complications in LE free flap reconstruction. METHODS: A retrospective cohort study was conducted using a prospectively maintained database of patients undergoing LE microsurgical reconstruction at a single academic institution from 2015 to 2024. Inclusion criteria were patients ≥ 18 years with documented perioperative transfusion data and at least 3 months of postoperative follow-up. Data included patient demographics, comorbidities, injury and operative characteristics, flap details, hemoglobin levels, and detailed transfusion information. Primary outcomes were flap necrosis, flap loss, and any flap-related complications. Multivariable logistic regression analyses were performed to determine associations between transfusion timing, dose, and outcomes, adjusting for demographic and clinical confounders. RESULTS: Among 133 patients who received free flap LE reconstruction, 48 (36.1%) received perioperative transfusions. Multivariable analysis on propensity matched cohorts revealed intraoperative transfusions were significantly associated with flap loss (OR: 9.70 [1.46-198], p = 0.02), venous congestion (OR: 10.3 [1.20-162], p = 0.03), and surgical site infection (OR: 4.07 [1.06-18.7], p = 0.04). Total number of LE procedures was significantly associated with flap loss (OR: 1.26 [1.04-1.59], p = 0.02), while muscle flaps (OR: 0.07 [0.00-0.92], p = 0.04) and postoperative transfusions (OR: 16.2 [2.35-260], p < 0.01) were significantly associated with venous congestion. Higher doses of intraoperative transfusions were significantly associated with higher rates of flap loss (OR: 2.43 [1.18-8.78], p = 0.01) and venous congestion (OR: 2.42 [1.11-9.09], p = 0.02). Patients receiving perioperative transfusions had lower BMIs, larger wound surface areas, and more LE surgeries during their admission stay. CONCLUSIONS: Intraoperative blood transfusions during LE free flap reconstruction were associated with increased flap-related complications, whereas transfusions administered pre- or postoperatively appeared comparatively safer. These findings suggest the importance of optimizing preoperative hemoglobin levels and practicing cautious intraoperative transfusion strategies to improve surgical outcomes.

Authors

Institutions

Publication Details

Journal
Microsurgery
Published
2026-11-17
DOI
https://doi.org/10.1002/micr.70316
Primary Topic
Reconstructive Surgery and Microvascular Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

The Timing of Transfusion: Investigating Associations Between Intraoperative Blood Products and Flap Complications in Lower Extremity Free Tissue Reconstruction

Artur Manasyan, David A. Daar, Joseph Nicholas Carey, Eloise Wood Stanton et al.
Microsurgery
Reconstructive Surgery and Microvascular Techniques
article

The Timing of Transfusion: Investigating Associations Between Intraoperative Blood Products and Flap Complications in Lower Extremity Free Tissue Reconstruction

Artur Manasyan, David A. Daar, Joseph Nicholas Carey, Eloise Wood Stanton, Michael I. Kim, Emma C. Koesters, Claire G. Olivas, Amara Emeh
article en

Abstract

BACKGROUND: Microsurgical free flap reconstruction is pivotal for managing complex lower extremity (LE) defects. Although perioperative blood transfusions are frequently employed to manage anemia and hemodynamic stability, their impact on free flap outcomes, specifically related to timing, remains inadequately understood. This study examines how transfusion timing (preoperative, intraoperative, and postoperative) influences flap complications in LE free flap reconstruction. METHODS: A retrospective cohort study was conducted using a prospectively maintained database of patients undergoing LE microsurgical reconstruction at a single academic institution from 2015 to 2024. Inclusion criteria were patients ≥ 18 years with documented perioperative transfusion data and at least 3 months of postoperative follow-up. Data included patient demographics, comorbidities, injury and operative characteristics, flap details, hemoglobin levels, and detailed transfusion information. Primary outcomes were flap necrosis, flap loss, and any flap-related complications. Multivariable logistic regression analyses were performed to determine associations between transfusion timing, dose, and outcomes, adjusting for demographic and clinical confounders. RESULTS: Among 133 patients who received free flap LE reconstruction, 48 (36.1%) received perioperative transfusions. Multivariable analysis on propensity matched cohorts revealed intraoperative transfusions were significantly associated with flap loss (OR: 9.70 [1.46-198], p = 0.02), venous congestion (OR: 10.3 [1.20-162], p = 0.03), and surgical site infection (OR: 4.07 [1.06-18.7], p = 0.04). Total number of LE procedures was significantly associated with flap loss (OR: 1.26 [1.04-1.59], p = 0.02), while muscle flaps (OR: 0.07 [0.00-0.92], p = 0.04) and postoperative transfusions (OR: 16.2 [2.35-260], p < 0.01) were significantly associated with venous congestion. Higher doses of intraoperative transfusions were significantly associated with higher rates of flap loss (OR: 2.43 [1.18-8.78], p = 0.01) and venous congestion (OR: 2.42 [1.11-9.09], p = 0.02). Patients receiving perioperative transfusions had lower BMIs, larger wound surface areas, and more LE surgeries during their admission stay. CONCLUSIONS: Intraoperative blood transfusions during LE free flap reconstruction were associated with increased flap-related complications, whereas transfusions administered pre- or postoperatively appeared comparatively safer. These findings suggest the importance of optimizing preoperative hemoglobin levels and practicing cautious intraoperative transfusion strategies to improve surgical outcomes.

MicrosurgeryVol. 46(8)
University of Southern California (US)
Reconstructive Surgery and Microvascular Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon