A Cable Partial Discharge Denoising Method Based on RIME-VMD-IWT

Among the various online monitoring methods for assessing the insulation condition of high-voltage cables, partial discharge (PD) detection is among the most widely applied. However, PD signals acquired in field environments are highly susceptible to noise interference. To address this issue, this paper proposes a PD signal denoising method that integrates the Rime Optimization Algorithm (RIME) with Variational Mode Decomposition (VMD) and Improved Wavelet Threshold (IWT) denoising. First, the RIME algorithm adaptively optimizes the number of modes K and the penalty factor α in VMD. The optimized VMD then decomposes the noisy PD signal into K intrinsic mode functions (IMFs), and the Composite Multiscale Fuzzy Dispersion Entropy (CMFDE) is introduced to characterize each IMF, thereby distinguishing effective signal components from noise components. Finally, IWT is applied to the effective components for secondary denoising to suppress residual noise and reconstruct the denoised PD signal. Simulation experiments and field-measured data demonstrate that the proposed method effectively removes noise interference in high-voltage cable PD signals and significantly improves the signal-to-noise ratio and reconstruction accuracy, enabling accurate online monitoring of high-voltage cable insulation condition.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-18
DOI
https://doi.org/10.21203/rs.3.rs-10161442/v1
Primary Topic
High voltage insulation and dielectric phenomena
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

A Cable Partial Discharge Denoising Method Based on RIME-VMD-IWT

刘乐乐, 贺益康, Su Lan, Yun Wang et al.
1 links
Research Square
High voltage insulation and dielectric phenomena
preprint

A Cable Partial Discharge Denoising Method Based on RIME-VMD-IWT

刘乐乐, 贺益康, Su Lan, Yun Wang, Ke Shang, Jianwei Song, Xiao Liu
preprint en

Abstract

Among the various online monitoring methods for assessing the insulation condition of high-voltage cables, partial discharge (PD) detection is among the most widely applied. However, PD signals acquired in field environments are highly susceptible to noise interference. To address this issue, this paper proposes a PD signal denoising method that integrates the Rime Optimization Algorithm (RIME) with Variational Mode Decomposition (VMD) and Improved Wavelet Threshold (IWT) denoising. First, the RIME algorithm adaptively optimizes the number of modes K and the penalty factor α in VMD. The optimized VMD then decomposes the noisy PD signal into K intrinsic mode functions (IMFs), and the Composite Multiscale Fuzzy Dispersion Entropy (CMFDE) is introduced to characterize each IMF, thereby distinguishing effective signal components from noise components. Finally, IWT is applied to the effective components for secondary denoising to suppress residual noise and reconstruct the denoised PD signal. Simulation experiments and field-measured data demonstrate that the proposed method effectively removes noise interference in high-voltage cable PD signals and significantly improves the signal-to-noise ratio and reconstruction accuracy, enabling accurate online monitoring of high-voltage cable insulation condition.

Research Square
State Grid Corporation of China (China) (CN), Tsinghua Sichuan Energy Internet Research Institute (CN)
Industry, innovation and infrastructure
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon