A temporary fix: assessing the safety, efficacy, and various applications of temporary externalized pacemakers

BACKGROUND: Temporary active-fixation pacemakers (TAF-PMs), consisting of a screw-in pacing lead connected to an external generator, may offer advantages over conventional balloon-tipped temporary pacemakers, including more secure lead placement, greater patient mobility, and reduced need for intensive care monitoring. We evaluated the safety and clinical utility of this strategy across multiple pacing indications. METHODS: We conducted a single-center, retrospective study of 100 adults who underwent TAF-PM placement between June 2019 and November 2024. Through chart review, data were collected on demographics, pacing indications, duration of temporary pacing, complications, and subsequent need for permanent pacemaker implantation (PPMI). The primary outcome was successful discontinuation of temporary pacing without subsequent PPMI. RESULTS: Pacing indications included spontaneous progression of conduction system disease (60%), transcatheter aortic valve replacement (TAVR)-related conduction abnormalities (12%), acute myocardial infarction (AMI)-related conduction abnormalities (12%), and ongoing infection precluding PPMI (16%). Thirty-eight patients (38%) did not undergo subsequent PPMI. Among patients with TAVR- and AMI-related conduction abnormalities, 75% avoided PPMI. Three patients (3%) experienced lead dislodgement. No new infections, lead perforations, significant bleeding, or cardiac arrests attributable to the TAF-PM strategy were documented. CONCLUSION: Temporary pacing using a screw-in lead affixed to an external generator is safe, effective, and reversible across multiple clinical scenarios, allowing sufficient time to assess the need for permanent pacing.

Authors

Institutions

Publication Details

Journal
Baylor University Medical Center Proceedings
Published
2026-11-18
DOI
https://doi.org/10.1080/08998280.2026.2762258
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A temporary fix: assessing the safety, efficacy, and various applications of temporary externalized pacemakers

Robert Jay Widmer, Javier E. Banchs, Levi Schiefer, Timothy A. Mixon et al.
Baylor University Medical Center Proceedings
Cardiac pacing and defibrillation studies
article

A temporary fix: assessing the safety, efficacy, and various applications of temporary externalized pacemakers

Robert Jay Widmer, Javier E. Banchs, Levi Schiefer, Timothy A. Mixon, JOSÉ EMILIO EXAIRE, Gillian Sheppard, Alisa King
article en

Abstract

BACKGROUND: Temporary active-fixation pacemakers (TAF-PMs), consisting of a screw-in pacing lead connected to an external generator, may offer advantages over conventional balloon-tipped temporary pacemakers, including more secure lead placement, greater patient mobility, and reduced need for intensive care monitoring. We evaluated the safety and clinical utility of this strategy across multiple pacing indications. METHODS: We conducted a single-center, retrospective study of 100 adults who underwent TAF-PM placement between June 2019 and November 2024. Through chart review, data were collected on demographics, pacing indications, duration of temporary pacing, complications, and subsequent need for permanent pacemaker implantation (PPMI). The primary outcome was successful discontinuation of temporary pacing without subsequent PPMI. RESULTS: Pacing indications included spontaneous progression of conduction system disease (60%), transcatheter aortic valve replacement (TAVR)-related conduction abnormalities (12%), acute myocardial infarction (AMI)-related conduction abnormalities (12%), and ongoing infection precluding PPMI (16%). Thirty-eight patients (38%) did not undergo subsequent PPMI. Among patients with TAVR- and AMI-related conduction abnormalities, 75% avoided PPMI. Three patients (3%) experienced lead dislodgement. No new infections, lead perforations, significant bleeding, or cardiac arrests attributable to the TAF-PM strategy were documented. CONCLUSION: Temporary pacing using a screw-in lead affixed to an external generator is safe, effective, and reversible across multiple clinical scenarios, allowing sufficient time to assess the need for permanent pacing.

Baylor University Medical Center Proceedings
Mary Washington Hospital (US), Baylor Scott & White Medical Center - Temple (US), Baylor Scott & White Health (US)
Good health and well-being
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon