A temporary fix: assessing the safety, efficacy, and various applications of temporary externalized pacemakers
BACKGROUND: Temporary active-fixation pacemakers (TAF-PMs), consisting of a screw-in pacing lead connected to an external generator, may offer advantages over conventional balloon-tipped temporary pacemakers, including more secure lead placement, greater patient mobility, and reduced need for intensive care monitoring. We evaluated the safety and clinical utility of this strategy across multiple pacing indications. METHODS: We conducted a single-center, retrospective study of 100 adults who underwent TAF-PM placement between June 2019 and November 2024. Through chart review, data were collected on demographics, pacing indications, duration of temporary pacing, complications, and subsequent need for permanent pacemaker implantation (PPMI). The primary outcome was successful discontinuation of temporary pacing without subsequent PPMI. RESULTS: Pacing indications included spontaneous progression of conduction system disease (60%), transcatheter aortic valve replacement (TAVR)-related conduction abnormalities (12%), acute myocardial infarction (AMI)-related conduction abnormalities (12%), and ongoing infection precluding PPMI (16%). Thirty-eight patients (38%) did not undergo subsequent PPMI. Among patients with TAVR- and AMI-related conduction abnormalities, 75% avoided PPMI. Three patients (3%) experienced lead dislodgement. No new infections, lead perforations, significant bleeding, or cardiac arrests attributable to the TAF-PM strategy were documented. CONCLUSION: Temporary pacing using a screw-in lead affixed to an external generator is safe, effective, and reversible across multiple clinical scenarios, allowing sufficient time to assess the need for permanent pacing.
Authors
- Robert Jay Widmer (ORCID: https://orcid.org/0000-0002-3063-5651)
- Javier E. Banchs (ORCID: https://orcid.org/0000-0002-7648-2873)
- Levi Schiefer (ORCID: https://orcid.org/0009-0004-9338-8258)
- Timothy A. Mixon (ORCID: https://orcid.org/0000-0002-0568-817X)
- JOSÉ EMILIO EXAIRE (ORCID: https://orcid.org/0000-0002-9198-8522)
- Gillian Sheppard
- Alisa King
Institutions
- Mary Washington Hospital (US)
- Baylor Scott & White Medical Center - Temple (US)
- Baylor Scott & White Health (US)
Publication Details
- Journal
- Baylor University Medical Center Proceedings
- Published
- 2026-11-18
- DOI
- https://doi.org/10.1080/08998280.2026.2762258
- Primary Topic
- Cardiac pacing and defibrillation studies
- Type
- article
- Field-Weighted Citation Impact
- 0.00