Compromised flushing fluid neutrality during sequential chemotherapy administration: an observational study

BACKGROUND: Maintaining the neutrality of flushing fluid is essential to keep patients safe from potential drug interaction and to protect nurses from potential exposure risk to hazardous drugs used in systemic anti-cancer therapy (SACT) when disconnecting infusion lines. AIMS: To investigate whether flushing fluid bags contained cross-contamination from chemotherapy drugs administered within the same regimen. METHODS: 94 flushing bags, representing 9 chemotherapy treatment regimens administered by 21 nurses, were collected. Liquid was collected from the flushing bags and analysed for 8 chemotherapy drugs. FINDINGS: Contamination with 1 or 2 drugs was detected in 14% of the flushing bags in 4 of 9 regimens, and 43% of the nurses were involved in its administration. Overall, only 83% of the prescribed flushing volume was administered. CONCLUSION: The findings highlight the need for improvement of engineering and administrative controls to reduce chemotherapy drugs' cross-contamination risks and enhance safety for both patients and nursing staff.

Authors

Institutions

Publication Details

Journal
British Journal of Nursing
Published
2026-11-18
DOI
https://doi.org/10.12968/bjon.2026.0337
Primary Topic
Safe Handling of Antineoplastic Drugs
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Compromised flushing fluid neutrality during sequential chemotherapy administration: an observational study

Paul J. M. Sessink, Monika Rezvanfar, Suzanne Jörnvik Carlsson
British Journal of Nursing
Safe Handling of Antineoplastic Drugs
article

Compromised flushing fluid neutrality during sequential chemotherapy administration: an observational study

Paul J. M. Sessink, Monika Rezvanfar, Suzanne Jörnvik Carlsson
article en

Abstract

BACKGROUND: Maintaining the neutrality of flushing fluid is essential to keep patients safe from potential drug interaction and to protect nurses from potential exposure risk to hazardous drugs used in systemic anti-cancer therapy (SACT) when disconnecting infusion lines. AIMS: To investigate whether flushing fluid bags contained cross-contamination from chemotherapy drugs administered within the same regimen. METHODS: 94 flushing bags, representing 9 chemotherapy treatment regimens administered by 21 nurses, were collected. Liquid was collected from the flushing bags and analysed for 8 chemotherapy drugs. FINDINGS: Contamination with 1 or 2 drugs was detected in 14% of the flushing bags in 4 of 9 regimens, and 43% of the nurses were involved in its administration. Overall, only 83% of the prescribed flushing volume was administered. CONCLUSION: The findings highlight the need for improvement of engineering and administrative controls to reduce chemotherapy drugs' cross-contamination risks and enhance safety for both patients and nursing staff.

British Journal of NursingVol. 35(21)
Sahlgrenska University Hospital (SE)
Good health and well-being
Safe Handling of Antineoplastic Drugs
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon