Microfluidics systems in ART: the current state of the problem

Introduction: changes in male reproductive function affect reproduction of offspring, failures of treatment using intrauterine insemination (IUI) and assisted reproductive technologies (ART), as well as miscarriage. This requires both a full-fledged diagnostic search and pathogenetic treatment of disorders of male reproductive function, as well as the development of methods that affect the effectiveness of IUI and ART. One of the promising methods of sperm breeding in IUI and ART is the use of microfluidics techniques. The aim of the study: review of current data on the possibilities of using microfluidics systems in ART. Results: microfluidics is a technology based on the principles of fluid flow in microchannels. When using different types of microfluidic devices, similar data have been published in the form of a significant decrease in the concentration and an increase in the proportion of progressively motile and morphologically normal forms of spermatozoa, a decrease in the level of fragmentation of sperm DNA. The use of microfluidic devices in azoospermia demonstrates good results compared to standard methods. According to the limited data published, microfluidic devices do not allow for selection aimed at increasing the proportion of euploid embryos. In terms of clinical pregnancy and pregnancy loss after ART, the effectiveness of the microfluidic devices used demonstrates insignificant positive results compared to standard methods of sperm selection, without statistical significance. Conclusion: the use of microfluidic devices in ART has become increasingly widespread in recent years. The published data confirm the promising nature of the technique and indicate both the need to develop new and improve existing microfluidic devices, as well as to develop criteria for selecting patients to use these methods.

Authors

Institutions

Publication Details

Journal
Russian Journal of Human Reproduction
Published
2026-11-18
DOI
https://doi.org/10.17116/repro20263205164
Primary Topic
Sperm and Testicular Function
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Microfluidics systems in ART: the current state of the problem

Vera G. Selyatitskaya, Maxim V. Shestakov, Е. А. Епанчинцева, Anna A. Yagodnitsyna
2 links
Russian Journal of Human Reproduction
Sperm and Testicular Function
article

Microfluidics systems in ART: the current state of the problem

Vera G. Selyatitskaya, Maxim V. Shestakov, Е. А. Епанчинцева, Anna A. Yagodnitsyna
article en

Abstract

Introduction: changes in male reproductive function affect reproduction of offspring, failures of treatment using intrauterine insemination (IUI) and assisted reproductive technologies (ART), as well as miscarriage. This requires both a full-fledged diagnostic search and pathogenetic treatment of disorders of male reproductive function, as well as the development of methods that affect the effectiveness of IUI and ART. One of the promising methods of sperm breeding in IUI and ART is the use of microfluidics techniques. The aim of the study: review of current data on the possibilities of using microfluidics systems in ART. Results: microfluidics is a technology based on the principles of fluid flow in microchannels. When using different types of microfluidic devices, similar data have been published in the form of a significant decrease in the concentration and an increase in the proportion of progressively motile and morphologically normal forms of spermatozoa, a decrease in the level of fragmentation of sperm DNA. The use of microfluidic devices in azoospermia demonstrates good results compared to standard methods. According to the limited data published, microfluidic devices do not allow for selection aimed at increasing the proportion of euploid embryos. In terms of clinical pregnancy and pregnancy loss after ART, the effectiveness of the microfluidic devices used demonstrates insignificant positive results compared to standard methods of sperm selection, without statistical significance. Conclusion: the use of microfluidic devices in ART has become increasingly widespread in recent years. The published data confirm the promising nature of the technique and indicate both the need to develop new and improve existing microfluidic devices, as well as to develop criteria for selecting patients to use these methods.

Russian Journal of Human ReproductionVol. 32(5)
Novosibirsk State Medical University (RU), Siberian Branch of the Russian Academy of Sciences (RU), Federal Research Center of Fundamental and Translational Medicine (RU), Institute of Thermophysics (RU)
Good health and well-being
Sperm and Testicular Function
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon