Elflow: Automated Quality Control and Self-Supervised Representation Learning for High-Dimensional Cytometry

High-dimensional flow and mass cytometry are foundational technologies for clinical immunophenotyping and hematological diagnostics, yet computational data analysis remains bottlenecked by operator-subjective manual gating. While computational tools have emerged, they remain fragmented across isolated tasks such as quality control or discrete clustering, leaving an unmet need for integrated, modular workflows that resolve continuous biological variation without manual supervision. Here, we introduce Elflow, a modular, self-supervised framework that links automated quality control, single-cell representation learning, and patient-level modeling without manual gating at inference. Elflow couples automated machine-learning quality control with Variance-Invariance-Covariance Regularization (VICReg) to learn continuous, batch-resilient single-cell representations without negative pairs or hand-labeled training sets. Across four diverse public benchmarks, Elflow adapts to distinct biological panels and clinical objectives. On 22-channel spectral flow cytometry (OMIP-030), self-supervised embeddings preserve fine functional T-cell gradations and outperform classical baselines in unsupervised clustering, while an anchor-guided extension accurately reproduces canonical manual gating hierarchies. On hand-curated CyTOF panels (Levine-13), linear PCA matches deep models, establishing an empirical boundary condition where linear methods suffice. Across multi-center clinical cohorts (FlowCAP-II), Elflow representations achieve high diagnostic sensitivity for acute myeloid leukemia across heterogeneous instruments despite severe class imbalance. In longitudinal immune monitoring (FlowCAP-IV), patient mean embeddings and micro-cluster differential histograms preserve rare antigen-specific responses, yielding significant AIDS-free survival stratification. By uniting automated quality control, self-supervised representation learning, and multi-scale patient aggregation, Elflow provides a modular, reproducibly benchmarked framework for high-parameter and multi-center translational cytometry.

Authors

Institutions

Publication Details

Journal
bioRxiv (Cold Spring Harbor Laboratory)
Published
2026-11-18
DOI
https://doi.org/10.64898/2026.11.17.767309
Primary Topic
Single-cell and spatial transcriptomics
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Elflow: Automated Quality Control and Self-Supervised Representation Learning for High-Dimensional Cytometry

Yogesh Kalakoti, Vaibhav Mittal, Maura Gasparetto, Abhishek Jha et al.
2 links
bioRxiv (Cold Spring Harbor Laboratory)
Single-cell and spatial transcriptomics
preprint

Elflow: Automated Quality Control and Self-Supervised Representation Learning for High-Dimensional Cytometry

Yogesh Kalakoti, Vaibhav Mittal, Maura Gasparetto, Abhishek Jha, Sachin Kumar Gupta
preprint en

Abstract

High-dimensional flow and mass cytometry are foundational technologies for clinical immunophenotyping and hematological diagnostics, yet computational data analysis remains bottlenecked by operator-subjective manual gating. While computational tools have emerged, they remain fragmented across isolated tasks such as quality control or discrete clustering, leaving an unmet need for integrated, modular workflows that resolve continuous biological variation without manual supervision. Here, we introduce Elflow, a modular, self-supervised framework that links automated quality control, single-cell representation learning, and patient-level modeling without manual gating at inference. Elflow couples automated machine-learning quality control with Variance-Invariance-Covariance Regularization (VICReg) to learn continuous, batch-resilient single-cell representations without negative pairs or hand-labeled training sets. Across four diverse public benchmarks, Elflow adapts to distinct biological panels and clinical objectives. On 22-channel spectral flow cytometry (OMIP-030), self-supervised embeddings preserve fine functional T-cell gradations and outperform classical baselines in unsupervised clustering, while an anchor-guided extension accurately reproduces canonical manual gating hierarchies. On hand-curated CyTOF panels (Levine-13), linear PCA matches deep models, establishing an empirical boundary condition where linear methods suffice. Across multi-center clinical cohorts (FlowCAP-II), Elflow representations achieve high diagnostic sensitivity for acute myeloid leukemia across heterogeneous instruments despite severe class imbalance. In longitudinal immune monitoring (FlowCAP-IV), patient mean embeddings and micro-cluster differential histograms preserve rare antigen-specific responses, yielding significant AIDS-free survival stratification. By uniting automated quality control, self-supervised representation learning, and multi-scale patient aggregation, Elflow provides a modular, reproducibly benchmarked framework for high-parameter and multi-center translational cytometry.

bioRxiv (Cold Spring Harbor Laboratory)
University of Colorado Anschutz Medical Campus (US)
Good health and well-being
Single-cell and spatial transcriptomics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon