Mask-Guided Two-Stage Synthesis and Regional Quantitative Evaluation of Virtual Contrast-Enhanced Thoracic CT

Background/Objectives: Virtual contrast-enhanced CT (vCECT) synthesis may support imaging workflows when iodinated contrast administration is undesirable. However, whole-image similarity can obscure errors in localized vascular enhancement. We evaluated a mask-guided two-stage framework that couples spatially targeted enhancement with separate assessment of localization and synthesis. Methods: This retrospective study included 50 patients with 2550 paired thoracic non-enhanced CT (NECT) and contrast-enhanced CT (CECT) slices from radiotherapy simulation. Stage 1 predicted a contrast-region mask from NECT; Stage 2 used this mask to guide residual synthesis, trained with locally blended pseudo-contrast targets. Localization was assessed using segmentation metrics, and synthesis was evaluated against reference CECT over the whole image and reference-mask regions of interest (ROIs). Ablations compared single-stage residual synthesis, predicted-mask guidance, and reference-mask guidance. Results: Mask prediction achieved a mean Dice similarity coefficient (DSC) of 0.91. Whole-image peak signal-to-noise ratio (PSNR) and structural similarity index were 46.91 dB and 0.96, respectively; ROI values were 34.22 dB and 0.95. Compared with single-stage synthesis, predicted-mask guidance increased ROI PSNR from 18.97 to 34.22 dB and reduced normalized root mean squared error from 0.12 to 0.03. Reference-mask guidance achieved an ROI PSNR of 36.13 dB. Conclusions: Explicit localization improved regional synthesis fidelity in this cohort. The framework links localized CT enhancement to quantitative image-quality evaluation; external and reader-based validation remain necessary before clinical use.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-11-18
DOI
https://doi.org/10.3390/diagnostics16223864
Primary Topic
Image Enhancement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Mask-Guided Two-Stage Synthesis and Regional Quantitative Evaluation of Virtual Contrast-Enhanced Thoracic CT

Kwan-Woo Lee, Kyuseok Kim, Kangmin Lee, Minsik Lee et al.
4 links
Diagnostics
Image Enhancement Techniques
article

Mask-Guided Two-Stage Synthesis and Regional Quantitative Evaluation of Virtual Contrast-Enhanced Thoracic CT

Kwan-Woo Lee, Kyuseok Kim, Kangmin Lee, Minsik Lee, Jun-Bong Shin
article en

Abstract

Background/Objectives: Virtual contrast-enhanced CT (vCECT) synthesis may support imaging workflows when iodinated contrast administration is undesirable. However, whole-image similarity can obscure errors in localized vascular enhancement. We evaluated a mask-guided two-stage framework that couples spatially targeted enhancement with separate assessment of localization and synthesis. Methods: This retrospective study included 50 patients with 2550 paired thoracic non-enhanced CT (NECT) and contrast-enhanced CT (CECT) slices from radiotherapy simulation. Stage 1 predicted a contrast-region mask from NECT; Stage 2 used this mask to guide residual synthesis, trained with locally blended pseudo-contrast targets. Localization was assessed using segmentation metrics, and synthesis was evaluated against reference CECT over the whole image and reference-mask regions of interest (ROIs). Ablations compared single-stage residual synthesis, predicted-mask guidance, and reference-mask guidance. Results: Mask prediction achieved a mean Dice similarity coefficient (DSC) of 0.91. Whole-image peak signal-to-noise ratio (PSNR) and structural similarity index were 46.91 dB and 0.96, respectively; ROI values were 34.22 dB and 0.95. Compared with single-stage synthesis, predicted-mask guidance increased ROI PSNR from 18.97 to 34.22 dB and reduced normalized root mean squared error from 0.12 to 0.03. Reference-mask guidance achieved an ROI PSNR of 36.13 dB. Conclusions: Explicit localization improved regional synthesis fidelity in this cohort. The framework links localized CT enhancement to quantitative image-quality evaluation; external and reader-based validation remain necessary before clinical use.

DiagnosticsVol. 16(22)
Gachon University (KR), Korea University (KR), Sejong University (KR), Kangwon National University Hospital (KR), Bio-Medical Science (South Korea) (KR), Korea University Anam Hospital (KR)
Good health and well-being
Image Enhancement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon