Bias-resilient ECG waveform modeling for rapid differentiation of stanford type-A aortic syndrome from STEMI

Stanford type-A aortic syndrome (TAAS) and ST-segment elevation myocardial infarction (STEMI) are time-critical cardiovascular emergencies that can show overlapping electrocardiographic findings but require fundamentally different treatment strategies. Differentiation at the first ECG assessment is therefore critical, yet labeled ECG resources for this task remain scarce, especially for physician-confirmed TAAS cases from emergency-care settings. Here, we introduce the Anzhen Dataset, a paper-based 12-lead ECG cohort comprising 728 first-admission records from 344 TAAS and 384 STEMI patients, providing a clinically grounded resource for this underexplored differential diagnosis task. We also identify a shortcut-learning risk in direct paper-ECG image classification, in which visual models exploit non-physiological image cues rather than electrophysiological morphology, limiting their reliability in real-world application scenarios. To reduce this risk, we propose a bias-resilient waveform modeling framework that converts paper ECGs into standardized 12-lead one-dimensional signals through perspective correction, lead localization, grid and noise removal, waveform digitization, and interpolation-based compensation. A lightweight ConvNeXt-Femto model then combines morphological analysis, low-rank feature compression, and lead-region relational attention to capture local waveform differences and cross-lead pathological consistency. In the TAAS–STEMI task, the model achieved 0.900 accuracy and 0.906 F1-score with 61,850 trainable parameters and a classifier inference latency of 4.010 ms per sample. Multi-class experiments, ablation studies, and visualization analyses further supported the model’s representation ability, module contribution, and physiological interpretability. These proof-of-concept findings support waveform-centered modeling as a lightweight approach that reduces image-related bias in TAAS–STEMI differentiation from paper-based ECGs; the model is intended only for preliminary risk stratification and cannot replace confirmatory imaging.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-11-17
DOI
https://doi.org/10.1038/s41598-026-80139-3
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Bias-resilient ECG waveform modeling for rapid differentiation of stanford type-A aortic syndrome from STEMI

Junjie Wang, Yanlong Ren, Yuan Li, Tian He et al.
Scientific Reports
ECG Monitoring and Analysis
article

Bias-resilient ECG waveform modeling for rapid differentiation of stanford type-A aortic syndrome from STEMI

Junjie Wang, Yanlong Ren, Yuan Li, Tian He, Zhenghao Xu, Yihan Xu, Xian-Tao Song, Zhanfeng Guo, Daixuan Wu
article en

Abstract

Stanford type-A aortic syndrome (TAAS) and ST-segment elevation myocardial infarction (STEMI) are time-critical cardiovascular emergencies that can show overlapping electrocardiographic findings but require fundamentally different treatment strategies. Differentiation at the first ECG assessment is therefore critical, yet labeled ECG resources for this task remain scarce, especially for physician-confirmed TAAS cases from emergency-care settings. Here, we introduce the Anzhen Dataset, a paper-based 12-lead ECG cohort comprising 728 first-admission records from 344 TAAS and 384 STEMI patients, providing a clinically grounded resource for this underexplored differential diagnosis task. We also identify a shortcut-learning risk in direct paper-ECG image classification, in which visual models exploit non-physiological image cues rather than electrophysiological morphology, limiting their reliability in real-world application scenarios. To reduce this risk, we propose a bias-resilient waveform modeling framework that converts paper ECGs into standardized 12-lead one-dimensional signals through perspective correction, lead localization, grid and noise removal, waveform digitization, and interpolation-based compensation. A lightweight ConvNeXt-Femto model then combines morphological analysis, low-rank feature compression, and lead-region relational attention to capture local waveform differences and cross-lead pathological consistency. In the TAAS–STEMI task, the model achieved 0.900 accuracy and 0.906 F1-score with 61,850 trainable parameters and a classifier inference latency of 4.010 ms per sample. Multi-class experiments, ablation studies, and visualization analyses further supported the model’s representation ability, module contribution, and physiological interpretability. These proof-of-concept findings support waveform-centered modeling as a lightweight approach that reduces image-related bias in TAAS–STEMI differentiation from paper-based ECGs; the model is intended only for preliminary risk stratification and cannot replace confirmatory imaging.

Scientific Reports
Xidian University (CN), Capital Medical University (CN), Purdue University West Lafayette (US), Beijing Anzhen Hospital (CN), Beijing Friendship Hospital (CN), Beijing National Research Center for Information Science and Technology (CN), Tsinghua University (CN)
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon