The comparison and application of the measurement method for radon progeny activity size distribution based on SDB and MLP

To achieve the accurate measurement of the activity size distribution of radon progeny and identify the distribution mode automatically, a measurement method based on the screen diffusion battery (SDB) and the Multilayer Perceptron (MLP) machine learning algorithm was developed in this study. Comparison experiments and field measurements were also carried out. Results show that the MLP algorithm presents superior performance in accurately identifying the unimodal or bimodal distribution and avoiding unambiguous solutions compared with the traditional ex-pectation maximization (EM) and Twomey inversion algorithms. Meanwhile, the SDB+MLP method proposed in this study has principle-based advantages over the conventional impactor method and SMPS indirect measurement method for solving parameters and the fraction of small-sized nucleation mode radon progeny. Field measurement results show that the SDB+MLP system can be applied to the activity size distribution measurement of the attached radon progeny. And the activity size distribution of the attached radon progeny in the outdoor environment all exhibits a bimodal distribution with the average diameter of the nucleation mode is 22 nm and that of the accumulation mode is 229 nm, and only a small portion of those show a unimodal distribution in the indoor environment, while the average diameters of the nucleation mode and accumulation mode separately are 25 nm and 209 nm. For the average fraction of the accumulation mode, a little difference of 66% and 69% for indoors and outdoors is shown, and the range is from 52% to 84% for outdoors and 49% to 87% for indoors. .

Authors

Institutions

Publication Details

Journal
Journal of Radiological Protection
Published
2026-11-18
DOI
https://doi.org/10.1088/1361-6498/aec3ac
Primary Topic
Radioactivity and Radon Measurements
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

The comparison and application of the measurement method for radon progeny activity size distribution based on SDB and MLP

L Zhang, Jinmin Yang, Duanyang Ma, 康 彭
2 links
Journal of Radiological Protection
Radioactivity and Radon Measurements
article

The comparison and application of the measurement method for radon progeny activity size distribution based on SDB and MLP

L Zhang, Jinmin Yang, Duanyang Ma, 康 彭
article en

Abstract

To achieve the accurate measurement of the activity size distribution of radon progeny and identify the distribution mode automatically, a measurement method based on the screen diffusion battery (SDB) and the Multilayer Perceptron (MLP) machine learning algorithm was developed in this study. Comparison experiments and field measurements were also carried out. Results show that the MLP algorithm presents superior performance in accurately identifying the unimodal or bimodal distribution and avoiding unambiguous solutions compared with the traditional ex-pectation maximization (EM) and Twomey inversion algorithms. Meanwhile, the SDB+MLP method proposed in this study has principle-based advantages over the conventional impactor method and SMPS indirect measurement method for solving parameters and the fraction of small-sized nucleation mode radon progeny. Field measurement results show that the SDB+MLP system can be applied to the activity size distribution measurement of the attached radon progeny. And the activity size distribution of the attached radon progeny in the outdoor environment all exhibits a bimodal distribution with the average diameter of the nucleation mode is 22 nm and that of the accumulation mode is 229 nm, and only a small portion of those show a unimodal distribution in the indoor environment, while the average diameters of the nucleation mode and accumulation mode separately are 25 nm and 209 nm. For the average fraction of the accumulation mode, a little difference of 66% and 69% for indoors and outdoors is shown, and the range is from 52% to 84% for outdoors and 49% to 87% for indoors. .

Journal of Radiological Protection
Peking University (CN)
National Natural Science Foundation of China
Radioactivity and Radon Measurements
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon