Interfacial defect sensitivity and failure-site competition in biomimetic mushroom-shaped micropillar adhesion
≤ 0.4). Defect geometry also plays an important role. For sector-shaped edge defects, radial penetration depth is a more critical geometric descriptor than circumferential length, because deeper penetration into the load-bearing contact region produces more severe degradation of pull-off force. Under dual-defect conditions, adhesion degradation does not follow linear area superposition. Instead, global failure is controlled by the defect that first reaches the critical debonding condition, with sufficiently large or deeply penetrating edge defects more likely to dominate failure. These findings reveal the mechanical link between defect geometry, structural compliance, and global adhesive failure, providing a basis for the defect-tolerant design of robust bioinspired dry adhesives.