Standard-Model-Extension Coefficients from the SYRTE Caesium-Rubidium Fountain Comparison
Two atomic fountains, one running on caesium and one on rubidium, were compared for months at SYRTE, and the absence of any sidereal variation in their frequency difference limits the coefficients that parametrise Lorentz violation in the Standard-Model Extension. The fractional shift is 1.5 × 10^-16, the leading coefficient comes out at 1.875 × 10^-16, and the ratio to the published limit is 1.875. Five coefficients are stated, each the shift divided by its sensitivity, with the second coefficient at 2.5 × 10^-16 and the fifth at 5 × 10^-16. The shift in hertz is 1.379 × 10^-6 at a clock frequency of 9.193 × 10^9 hertz, over an averaging time of 8.64 × 10^4 seconds. The result is computed from the published comparison limit and the stated sensitivities, not measured here, and it is the microwave-clock anchor of the laboratory bounds in this set.
Authors
- William Alexander Aldred (ORCID: https://orcid.org/0009-0000-1215-577X)
Publication Details
- Journal
- Zenodo (CERN European Organization for Nuclear Research)
- Published
- 2026-11-18
- DOI
- https://doi.org/10.5281/zenodo.24332323
- Primary Topic
- Advanced Frequency and Time Standards
- Type
- article
- Field-Weighted Citation Impact
- 0.00