The burden of hidden fluid intake in critically ill patients: A retrospective stewardship study of fluid balance, illness severity, and exploratory clinical outcomes

Background: Hidden fluids from continuously infused medications, maintenance carrier infusions, and routine intensive care unit (ICU) flushes are often excluded from fluid accounting. This study quantified first-day hidden fluid burden and its ratio to total intake and explored associations with illness severity, fluid balance, and ICU disposition. Materials and methods: This single-center retrospective observational study included consecutive first ICU admissions from January 2021 to January 2022. Hidden fluids comprised micropump-delivered medications, micropump maintenance fluids, invasive or enteral tube flushes, and tubing rinse/flush fluids not routinely counted as planned intravenous fluids. The hidden volume ratio was calculated as hidden fluid divided by total first-day intake. Results: Of 328 screened ICU admissions, 243 were included. Mean hidden fluid volume was 796.3 ± 460.9 mL (median, 650.0 mL; interquartile range, 468.6–992.6), and the mean hidden volume ratio was 26.8% ± 12.1%. Micropump-delivered medications contributed the largest proportion (39.6%). Hidden fluid correlated modestly with Acute Physiology and Chronic Health Evaluation II ( r = 0.27, P < 0.001) and Sequential Organ Failure Assessment ( r = 0.21, P < 0.001) scores and was greater in patients with Acute Physiology and Chronic Health Evaluation II ≥25 and Sequential Organ Failure Assessment ≥6 (both P < 0.001). Hidden fluid correlated weakly with first-day fluid balance ( r = 0.18, P = 0.004) but was not associated with ICU length of stay or documented adverse ICU disposition after adjustment. Conclusions: Hidden fluids constituted a substantial, largely uncounted proportion of first-day ICU intake, predominantly from micropump-related sources. These sources represent practical targets for ICU fluid stewardship. Whether reducing hidden fluids improves clinical outcomes requires prospective evaluation.

Authors

Institutions

Publication Details

Journal
Hemodynamics
Published
2026-11-18
DOI
https://doi.org/10.1097/hd9.0000000000000039
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

The burden of hidden fluid intake in critically ill patients: A retrospective stewardship study of fluid balance, illness severity, and exploratory clinical outcomes

Mingying Dai, Jia Liu, Yuan Bian, Wei Yi Fang
Hemodynamics
Hemodynamic Monitoring and Therapy
article

The burden of hidden fluid intake in critically ill patients: A retrospective stewardship study of fluid balance, illness severity, and exploratory clinical outcomes

Mingying Dai, Jia Liu, Yuan Bian, Wei Yi Fang
article en

Abstract

Background: Hidden fluids from continuously infused medications, maintenance carrier infusions, and routine intensive care unit (ICU) flushes are often excluded from fluid accounting. This study quantified first-day hidden fluid burden and its ratio to total intake and explored associations with illness severity, fluid balance, and ICU disposition. Materials and methods: This single-center retrospective observational study included consecutive first ICU admissions from January 2021 to January 2022. Hidden fluids comprised micropump-delivered medications, micropump maintenance fluids, invasive or enteral tube flushes, and tubing rinse/flush fluids not routinely counted as planned intravenous fluids. The hidden volume ratio was calculated as hidden fluid divided by total first-day intake. Results: Of 328 screened ICU admissions, 243 were included. Mean hidden fluid volume was 796.3 ± 460.9 mL (median, 650.0 mL; interquartile range, 468.6–992.6), and the mean hidden volume ratio was 26.8% ± 12.1%. Micropump-delivered medications contributed the largest proportion (39.6%). Hidden fluid correlated modestly with Acute Physiology and Chronic Health Evaluation II ( r = 0.27, P < 0.001) and Sequential Organ Failure Assessment ( r = 0.21, P < 0.001) scores and was greater in patients with Acute Physiology and Chronic Health Evaluation II ≥25 and Sequential Organ Failure Assessment ≥6 (both P < 0.001). Hidden fluid correlated weakly with first-day fluid balance ( r = 0.18, P = 0.004) but was not associated with ICU length of stay or documented adverse ICU disposition after adjustment. Conclusions: Hidden fluids constituted a substantial, largely uncounted proportion of first-day ICU intake, predominantly from micropump-related sources. These sources represent practical targets for ICU fluid stewardship. Whether reducing hidden fluids improves clinical outcomes requires prospective evaluation.

Hemodynamics
Shandong University (CN), Shandong Provincial Hospital (CN), Affiliated Hospital of Qingdao University (CN), Qilu Hospital of Shandong University (CN), Shandong First Medical University (CN)
Good health and well-being
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon