Modeling Earth Returns and Analyzing Faults in SWER System with Heterogeneous Soils

Single wire earth return power lines use the ground as the normal path for return current. Their operating performance and response to faults therefore depend on soil properties. Conventional models generally assume homogeneous soil, although soil resistivity can vary with depth and along the line route. This study proposes an electrical model that accounts for both types of variation. An eighty-kilometer line is divided into ten longitudinal zones, and the Martins Britto formulation is used to represent the layered soil in each zone by an equivalent complex conductivity. The self and mutual impedances are then calculated for each zone. The loop impedance is obtained by subtracting twice the mutual impedance from the sum of the two self-impedances. The Carson formulation serves as the reference, while the Deri approximation supplies the parameters for simulations in Simulink. The model represents the earth return path in heterogeneous soils and supports preliminary engineering and safety assessments. Field measurements are needed to validate the model for a specific site.

Authors

Institutions

Publication Details

Journal
International Journal of Innovative Science and Research Technology (IJISRT)
Published
2026-11-18
DOI
https://doi.org/10.38124/ijisrt/26nov472
Primary Topic
High-Voltage Power Transmission Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Modeling Earth Returns and Analyzing Faults in SWER System with Heterogeneous Soils

RAMILISON Tsanta Fifaliana Andriamihaja, RAKOTONIAINA Solofo Hery, Harlin Samuel Andriatsihoarana
International Journal of Innovative Science and Research Technology (IJISRT)
High-Voltage Power Transmission Systems
article

Modeling Earth Returns and Analyzing Faults in SWER System with Heterogeneous Soils

RAMILISON Tsanta Fifaliana Andriamihaja, RAKOTONIAINA Solofo Hery, Harlin Samuel Andriatsihoarana
article en

Abstract

Single wire earth return power lines use the ground as the normal path for return current. Their operating performance and response to faults therefore depend on soil properties. Conventional models generally assume homogeneous soil, although soil resistivity can vary with depth and along the line route. This study proposes an electrical model that accounts for both types of variation. An eighty-kilometer line is divided into ten longitudinal zones, and the Martins Britto formulation is used to represent the layered soil in each zone by an equivalent complex conductivity. The self and mutual impedances are then calculated for each zone. The loop impedance is obtained by subtracting twice the mutual impedance from the sum of the two self-impedances. The Carson formulation serves as the reference, while the Deri approximation supplies the parameters for simulations in Simulink. The model represents the earth return path in heterogeneous soils and supports preliminary engineering and safety assessments. Field measurements are needed to validate the model for a specific site.

International Journal of Innovative Science and Research Technology (IJISRT)Vol. 11(11)
University of Antananarivo (MG)
High-Voltage Power Transmission Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon