Cancellation of cryocooler-induced vibration in trapped-ion systems

Mechanical cryocoolers offer numerous benefits for the operation of vacuum systems containing trapped atomic ions. However, the fidelity of laser-based gates can be degraded by phase noise induced by the cryocooler vibrations. We present a feed-forward vibration-cancellation system that directly measures inner shield displacement with an auxiliary interferometer and applies a compensating phase correction to the laser drive. The interferometer signal is demodulated, and a field-programmable gate array (FPGA) system unwraps the displacement measurement signal, computes the required correction phase, and updates the RF drive of an in-line acousto-optic modulator (AOM) to correct for the vibration-induced dephasing. With cancellation active, the qubit coherence time improves from $3.0\pm0.4$ ms to $35\pm5$ ms, consistent with a simulation based on the measured vibration spectrum. We further validate the cancellation by artificially increasing the mechanical coupling of the cryocooler to the vacuum chamber. The vibration-induced decoherence rate is suppressed by a factor of approximately 70 at an RMS (root mean square) displacement of 0.65 $\mathrmμ$m.

Authors

Publication Details

Journal
arXiv (Cornell University)
Published
2026-11-17
DOI
https://doi.org/10.48550/arxiv.2611.22872
Primary Topic
Quantum Information and Cryptography
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Cancellation of cryocooler-induced vibration in trapped-ion systems

Kyle DeBry, Colin Bruzewicz, Isaac L. Chuang, Alexandra Plocki et al.
arXiv (Cornell University)
Quantum Information and Cryptography
preprint

Cancellation of cryocooler-induced vibration in trapped-ion systems

Kyle DeBry, Colin Bruzewicz, Isaac L. Chuang, Alexandra Plocki, Robert McConnell, Agustin Valdes Martinez
preprint en

Abstract

Mechanical cryocoolers offer numerous benefits for the operation of vacuum systems containing trapped atomic ions. However, the fidelity of laser-based gates can be degraded by phase noise induced by the cryocooler vibrations. We present a feed-forward vibration-cancellation system that directly measures inner shield displacement with an auxiliary interferometer and applies a compensating phase correction to the laser drive. The interferometer signal is demodulated, and a field-programmable gate array (FPGA) system unwraps the displacement measurement signal, computes the required correction phase, and updates the RF drive of an in-line acousto-optic modulator (AOM) to correct for the vibration-induced dephasing. With cancellation active, the qubit coherence time improves from $3.0\pm0.4$ ms to $35\pm5$ ms, consistent with a simulation based on the measured vibration spectrum. We further validate the cancellation by artificially increasing the mechanical coupling of the cryocooler to the vacuum chamber. The vibration-induced decoherence rate is suppressed by a factor of approximately 70 at an RMS (root mean square) displacement of 0.65 $\mathrmμ$m.

arXiv (Cornell University)
Quantum Information and Cryptography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon